1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
308
309
310
311
312
313
314
315
316
317
318
319
320
321
322
323
324
325
326
327
328
329
330
331
332
333
334
335
336
337
338
339
340
341
342
343
344
345
346
347
348
349
350
351
352
353
354
355
356
357
358
359
360
361
362
363
364
365
366
367
368
369
370
371
372
373
374
375
376
377
378
379
380
381
382
383
384
385
386
387
388
389
390
391
392
393
394
395
396
397
398
399
400
401
402
403
404
405
406
407
408
409
410
411
412
413
414
415
416
417
418
419
420
421
422
423
424
425
426
427
428
429
430
431
432
433
434
435
436
437
438
439
440
441
442
443
444
445
446
447
448
449
450
451
452
453
454
455
456
457
458
459
460
461
462
463
464
465
466
467
468
469
470
471
472
473
474
475
476
477
478
479
480
481
482
483
484
485
486
487
488
489
490
491
492
|
#
# Generic thermal sysfs drivers configuration
#
menuconfig THERMAL
tristate "Generic Thermal sysfs driver"
help
Generic Thermal Sysfs driver offers a generic mechanism for
thermal management. Usually it's made up of one or more thermal
zone and cooling device.
Each thermal zone contains its own temperature, trip points,
cooling devices.
All platforms with ACPI thermal support can use this driver.
If you want this support, you should say Y or M here.
if THERMAL
config THERMAL_STATISTICS
bool "Thermal state transition statistics"
help
Export thermal state transition statistics information through sysfs.
If in doubt, say N.
config THERMAL_EMERGENCY_POWEROFF_DELAY_MS
int "Emergency poweroff delay in milli-seconds"
depends on THERMAL
default 0
help
Thermal subsystem will issue a graceful shutdown when
critical temperatures are reached using orderly_poweroff(). In
case of failure of an orderly_poweroff(), the thermal emergency
poweroff kicks in after a delay has elapsed and shuts down the system.
This config is number of milliseconds to delay before emergency
poweroff kicks in. Similarly to the critical trip point,
the delay should be carefully profiled so as to give adequate
time for orderly_poweroff() to finish on regular execution.
If set to 0 emergency poweroff will not be supported.
In doubt, leave as 0.
config THERMAL_HWMON
bool
prompt "Expose thermal sensors as hwmon device"
depends on HWMON=y || HWMON=THERMAL
default y
help
In case a sensor is registered with the thermal
framework, this option will also register it
as a hwmon. The sensor will then have the common
hwmon sysfs interface.
Say 'Y' here if you want all thermal sensors to
have hwmon sysfs interface too.
config THERMAL_OF
bool
prompt "APIs to parse thermal data out of device tree"
depends on OF
default y
help
This options provides helpers to add the support to
read and parse thermal data definitions out of the
device tree blob.
Say 'Y' here if you need to build thermal infrastructure
based on device tree.
config THERMAL_WRITABLE_TRIPS
bool "Enable writable trip points"
help
This option allows the system integrator to choose whether
trip temperatures can be changed from userspace. The
writable trips need to be specified when setting up the
thermal zone but the choice here takes precedence.
Say 'Y' here if you would like to allow userspace tools to
change trip temperatures.
choice
prompt "Default Thermal governor"
default THERMAL_DEFAULT_GOV_STEP_WISE
help
This option sets which thermal governor shall be loaded at
startup. If in doubt, select 'step_wise'.
config THERMAL_DEFAULT_GOV_STEP_WISE
bool "step_wise"
select THERMAL_GOV_STEP_WISE
help
Use the step_wise governor as default. This throttles the
devices one step at a time.
config THERMAL_DEFAULT_GOV_FAIR_SHARE
bool "fair_share"
select THERMAL_GOV_FAIR_SHARE
help
Use the fair_share governor as default. This throttles the
devices based on their 'contribution' to a zone. The
contribution should be provided through platform data.
config THERMAL_DEFAULT_GOV_USER_SPACE
bool "user_space"
select THERMAL_GOV_USER_SPACE
help
Select this if you want to let the user space manage the
platform thermals.
config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
bool "power_allocator"
select THERMAL_GOV_POWER_ALLOCATOR
help
Select this if you want to control temperature based on
system and device power allocation. This governor can only
operate on cooling devices that implement the power API.
endchoice
config THERMAL_GOV_FAIR_SHARE
bool "Fair-share thermal governor"
help
Enable this to manage platform thermals using fair-share governor.
config THERMAL_GOV_STEP_WISE
bool "Step_wise thermal governor"
help
Enable this to manage platform thermals using a simple linear
governor.
config THERMAL_GOV_BANG_BANG
bool "Bang Bang thermal governor"
default n
help
Enable this to manage platform thermals using bang bang governor.
Say 'Y' here if you want to use two point temperature regulation
used for fans without throttling. Some fan drivers depend on this
governor to be enabled (e.g. acerhdf).
config THERMAL_GOV_USER_SPACE
bool "User_space thermal governor"
help
Enable this to let the user space manage the platform thermals.
config THERMAL_GOV_POWER_ALLOCATOR
bool "Power allocator thermal governor"
help
Enable this to manage platform thermals by dynamically
allocating and limiting power to devices.
config CPU_THERMAL
bool "generic cpu cooling support"
depends on CPU_FREQ
depends on THERMAL_OF
help
This implements the generic cpu cooling mechanism through frequency
reduction. An ACPI version of this already exists
(drivers/acpi/processor_thermal.c).
This will be useful for platforms using the generic thermal interface
and not the ACPI interface.
If you want this support, you should say Y here.
config CLOCK_THERMAL
bool "Generic clock cooling support"
depends on COMMON_CLK
depends on PM_OPP
help
This entry implements the generic clock cooling mechanism through
frequency clipping. Typically used to cool off co-processors. The
device that is configured to use this cooling mechanism will be
controlled to reduce clock frequency whenever temperature is high.
config DEVFREQ_THERMAL
bool "Generic device cooling support"
depends on PM_DEVFREQ
depends on PM_OPP
help
This implements the generic devfreq cooling mechanism through
frequency reduction for devices using devfreq.
This will throttle the device by limiting the maximum allowed DVFS
frequency corresponding to the cooling level.
In order to use the power extensions of the cooling device,
devfreq should use the simple_ondemand governor.
If you want this support, you should say Y here.
config THERMAL_EMULATION
bool "Thermal emulation mode support"
help
Enable this option to make a emul_temp sysfs node in thermal zone
directory to support temperature emulation. With emulation sysfs node,
user can manually input temperature and test the different trip
threshold behaviour for simulation purpose.
WARNING: Be careful while enabling this option on production systems,
because userland can easily disable the thermal policy by simply
flooding this sysfs node with low temperature values.
config HISI_THERMAL
tristate "Hisilicon thermal driver"
depends on ARCH_HISI || COMPILE_TEST
depends on HAS_IOMEM
depends on OF
default y
help
Enable this to plug hisilicon's thermal sensor driver into the Linux
thermal framework. cpufreq is used as the cooling device to throttle
CPUs when the passive trip is crossed.
config IMX_THERMAL
tristate "Temperature sensor driver for Freescale i.MX SoCs"
depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST
depends on NVMEM || !NVMEM
depends on MFD_SYSCON
depends on OF
help
Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
It supports one critical trip point and one passive trip point. The
cpufreq is used as the cooling device to throttle CPUs when the
passive trip is crossed.
config MAX77620_THERMAL
tristate "Temperature sensor driver for Maxim MAX77620 PMIC"
depends on MFD_MAX77620
depends on OF
help
Support for die junction temperature warning alarm for Maxim
Semiconductor PMIC MAX77620 device. Device generates two alarm
interrupts when PMIC die temperature cross the threshold of
120 degC and 140 degC.
config QORIQ_THERMAL
tristate "QorIQ Thermal Monitoring Unit"
depends on THERMAL_OF
depends on HAS_IOMEM
help
Support for Thermal Monitoring Unit (TMU) found on QorIQ platforms.
It supports one critical trip point and one passive trip point. The
cpufreq is used as the cooling device to throttle CPUs when the
passive trip is crossed.
config SPEAR_THERMAL
tristate "SPEAr thermal sensor driver"
depends on PLAT_SPEAR || COMPILE_TEST
depends on HAS_IOMEM
depends on OF
help
Enable this to plug the SPEAr thermal sensor driver into the Linux
thermal framework.
config ROCKCHIP_THERMAL
tristate "Rockchip thermal driver"
depends on ARCH_ROCKCHIP || COMPILE_TEST
depends on RESET_CONTROLLER
depends on HAS_IOMEM
help
Rockchip thermal driver provides support for Temperature sensor
ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
trip point. Cpufreq is used as the cooling device and will throttle
CPUs when the Temperature crosses the passive trip point.
config RCAR_THERMAL
tristate "Renesas R-Car thermal driver"
depends on ARCH_RENESAS || COMPILE_TEST
depends on HAS_IOMEM
help
Enable this to plug the R-Car thermal sensor driver into the Linux
thermal framework.
config RCAR_GEN3_THERMAL
tristate "Renesas R-Car Gen3 thermal driver"
depends on ARCH_RENESAS || COMPILE_TEST
depends on HAS_IOMEM
depends on OF
help
Enable this to plug the R-Car Gen3 thermal sensor driver into the Linux
thermal framework.
config KIRKWOOD_THERMAL
tristate "Temperature sensor on Marvell Kirkwood SoCs"
depends on MACH_KIRKWOOD || COMPILE_TEST
depends on HAS_IOMEM
depends on OF
help
Support for the Kirkwood thermal sensor driver into the Linux thermal
framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
config DOVE_THERMAL
tristate "Temperature sensor on Marvell Dove SoCs"
depends on ARCH_DOVE || MACH_DOVE || COMPILE_TEST
depends on HAS_IOMEM
depends on OF
help
Support for the Dove thermal sensor driver in the Linux thermal
framework.
config DB8500_THERMAL
tristate "DB8500 thermal management"
depends on MFD_DB8500_PRCMU
default y
help
Adds DB8500 thermal management implementation according to the thermal
management framework. A thermal zone with several trip points will be
created. Cooling devices can be bound to the trip points to cool this
thermal zone if trip points reached.
config ARMADA_THERMAL
tristate "Marvell EBU Armada SoCs thermal management"
depends on ARCH_MVEBU || COMPILE_TEST
depends on HAS_IOMEM
depends on OF
help
Enable this option if you want to have support for thermal management
controller present in Marvell EBU Armada SoCs (370,375,XP,38x,7K,8K).
config DA9062_THERMAL
tristate "DA9062/DA9061 Dialog Semiconductor thermal driver"
depends on MFD_DA9062 || COMPILE_TEST
depends on OF
help
Enable this for the Dialog Semiconductor thermal sensor driver.
This will report PMIC junction over-temperature for one thermal trip
zone.
Compatible with the DA9062 and DA9061 PMICs.
config INTEL_POWERCLAMP
tristate "Intel PowerClamp idle injection driver"
depends on THERMAL
depends on X86
depends on CPU_SUP_INTEL
help
Enable this to enable Intel PowerClamp idle injection driver. This
enforce idle time which results in more package C-state residency. The
user interface is exposed via generic thermal framework.
config X86_PKG_TEMP_THERMAL
tristate "X86 package temperature thermal driver"
depends on X86_THERMAL_VECTOR
select THERMAL_GOV_USER_SPACE
select THERMAL_WRITABLE_TRIPS
default m
help
Enable this to register CPU digital sensor for package temperature as
thermal zone. Each package will have its own thermal zone. There are
two trip points which can be set by user to get notifications via thermal
notification methods.
config INTEL_SOC_DTS_IOSF_CORE
tristate
depends on X86 && PCI
select IOSF_MBI
help
This is becoming a common feature for Intel SoCs to expose the additional
digital temperature sensors (DTSs) using side band interface (IOSF). This
implements the common set of helper functions to register, get temperature
and get/set thresholds on DTSs.
config INTEL_SOC_DTS_THERMAL
tristate "Intel SoCs DTS thermal driver"
depends on X86 && PCI
select INTEL_SOC_DTS_IOSF_CORE
select THERMAL_WRITABLE_TRIPS
help
Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
temperature sensor (DTS). These SoCs have two additional DTSs in
addition to DTSs on CPU cores. Each DTS will be registered as a
thermal zone. There are two trip points. One of the trip point can
be set by user mode programs to get notifications via Linux thermal
notification methods.The other trip is a critical trip point, which
was set by the driver based on the TJ MAX temperature.
config INTEL_QUARK_DTS_THERMAL
tristate "Intel Quark DTS thermal driver"
depends on X86_INTEL_QUARK
help
Enable this to register Intel Quark SoC (e.g. X1000) platform digital
temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
The DTS will be registered as a thermal zone. There are two trip points:
hot & critical. The critical trip point default value is set by
underlying BIOS/Firmware.
menu "ACPI INT340X thermal drivers"
source drivers/thermal/int340x_thermal/Kconfig
endmenu
config INTEL_BXT_PMIC_THERMAL
tristate "Intel Broxton PMIC thermal driver"
depends on X86 && INTEL_SOC_PMIC_BXTWC && REGMAP
help
Select this driver for Intel Broxton PMIC with ADC channels monitoring
system temperature measurements and alerts.
This driver is used for monitoring the ADC channels of PMIC and handles
the alert trip point interrupts and notifies the thermal framework with
the trip point and temperature details of the zone.
config INTEL_PCH_THERMAL
tristate "Intel PCH Thermal Reporting Driver"
depends on X86 && PCI
help
Enable this to support thermal reporting on certain intel PCHs.
Thermal reporting device will provide temperature reading,
programmable trip points and other information.
config MTK_THERMAL
tristate "Temperature sensor driver for mediatek SoCs"
depends on ARCH_MEDIATEK || COMPILE_TEST
depends on HAS_IOMEM
depends on NVMEM || NVMEM=n
depends on RESET_CONTROLLER
default y
help
Enable this option if you want to have support for thermal management
controller present in Mediatek SoCs
menu "Broadcom thermal drivers"
depends on ARCH_BCM || ARCH_BRCMSTB || ARCH_BCM2835 || COMPILE_TEST
source "drivers/thermal/broadcom/Kconfig"
endmenu
menu "Texas Instruments thermal drivers"
depends on ARCH_HAS_BANDGAP || COMPILE_TEST
depends on HAS_IOMEM
source "drivers/thermal/ti-soc-thermal/Kconfig"
endmenu
menu "Samsung thermal drivers"
depends on ARCH_EXYNOS || COMPILE_TEST
source "drivers/thermal/samsung/Kconfig"
endmenu
menu "STMicroelectronics thermal drivers"
depends on (ARCH_STI || ARCH_STM32) && OF
source "drivers/thermal/st/Kconfig"
endmenu
config TANGO_THERMAL
tristate "Tango thermal management"
depends on ARCH_TANGO || COMPILE_TEST
help
Enable the Tango thermal driver, which supports the primitive
temperature sensor embedded in Tango chips since the SMP8758.
This sensor only generates a 1-bit signal to indicate whether
the die temperature exceeds a programmable threshold.
source "drivers/thermal/tegra/Kconfig"
config QCOM_SPMI_TEMP_ALARM
tristate "Qualcomm SPMI PMIC Temperature Alarm"
depends on OF && SPMI && IIO
select REGMAP_SPMI
help
This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
PMIC devices. It shows up in sysfs as a thermal sensor with multiple
trip points. The temperature reported by the thermal sensor reflects the
real time die temperature if an ADC is present or an estimate of the
temperature based upon the over temperature stage value.
config GENERIC_ADC_THERMAL
tristate "Generic ADC based thermal sensor"
depends on IIO
help
This enabled a thermal sysfs driver for the temperature sensor
which is connected to the General Purpose ADC. The ADC channel
is read via IIO framework and the channel information is provided
to this driver. This driver reports the temperature by reading ADC
channel and converts it to temperature based on lookup table.
menu "Qualcomm thermal drivers"
depends on (ARCH_QCOM && OF) || COMPILE_TEST
source "drivers/thermal/qcom/Kconfig"
endmenu
config ZX2967_THERMAL
tristate "Thermal sensors on zx2967 SoC"
depends on ARCH_ZX || COMPILE_TEST
help
Enable the zx2967 thermal sensors driver, which supports
the primitive temperature sensor embedded in zx2967 SoCs.
This sensor generates the real time die temperature.
config UNIPHIER_THERMAL
tristate "Socionext UniPhier thermal driver"
depends on ARCH_UNIPHIER || COMPILE_TEST
depends on THERMAL_OF && MFD_SYSCON
help
Enable this to plug in UniPhier on-chip PVT thermal driver into the
thermal framework. The driver supports CPU thermal zone temperature
reporting and a couple of trip points.
endif
|