diff options
author | Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com> | 2019-05-02 15:03:51 +0200 |
---|---|---|
committer | Andy Shevchenko <andriy.shevchenko@linux.intel.com> | 2019-05-20 17:26:40 +0300 |
commit | d6423bd03031c020121da26c41a26bd5cc6d0da3 (patch) | |
tree | 36fb49837df45373469ff850be30ec77c12aa322 /drivers/platform/x86/pmc_atom.c | |
parent | 3d0818f5eba80fbe4c0addbfe6ddb2d19dc82cd4 (diff) |
platform/x86: pmc_atom: Add several Beckhoff Automation boards to critclk_systems DMI table
There are several Beckhoff Automation industrial PC boards which use
pmc_plt_clk* clocks for ethernet controllers. This adds affected boards
to critclk_systems DMI table so the clocks are marked as CLK_CRITICAL and
not turned off.
Fixes: 648e921888ad ("clk: x86: Stop marking clocks as CLK_IS_CRITICAL")
Signed-off-by: Steffen Dirkwinkel <s.dirkwinkel@beckhoff.com>
Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com>
Diffstat (limited to 'drivers/platform/x86/pmc_atom.c')
-rw-r--r-- | drivers/platform/x86/pmc_atom.c | 24 |
1 files changed, 24 insertions, 0 deletions
diff --git a/drivers/platform/x86/pmc_atom.c b/drivers/platform/x86/pmc_atom.c index a311f48ce7c9..b1d804376237 100644 --- a/drivers/platform/x86/pmc_atom.c +++ b/drivers/platform/x86/pmc_atom.c @@ -413,6 +413,30 @@ static const struct dmi_system_id critclk_systems[] = { DMI_MATCH(DMI_PRODUCT_NAME, "3I380D"), }, }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB3163", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB3163"), + }, + }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB6263", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB6263"), + }, + }, + { + /* pmc_plt_clk* - are used for ethernet controllers */ + .ident = "Beckhoff CB6363", + .matches = { + DMI_MATCH(DMI_SYS_VENDOR, "Beckhoff Automation"), + DMI_MATCH(DMI_BOARD_NAME, "CB6363"), + }, + }, { /*sentinel*/ } }; |