summaryrefslogtreecommitdiff
path: root/arch/x86
diff options
context:
space:
mode:
authorThomas Gleixner <tglx@linutronix.de>2016-02-22 22:19:23 +0000
committerIngo Molnar <mingo@kernel.org>2016-02-29 09:35:23 +0100
commit512089d98457b7913d2e4762a44af52fbcd87470 (patch)
tree218c00574cee19381dbf50a8bebf62300e841ef3 /arch/x86
parent75c7003fbf419f05215d4ca09bf3964d0b1c99e9 (diff)
perf/x86/intel/rapl: Clean up the printk output
The output is inconsistent. Use a proper pr_fmt prefix and split out the advertisement into a seperate function. Remove the WARN_ON() in the failure case. It's pointless as we already know where it failed. Signed-off-by: Thomas Gleixner <tglx@linutronix.de> Signed-off-by: Peter Zijlstra (Intel) <peterz@infradead.org> Cc: Andi Kleen <andi.kleen@intel.com> Cc: Arnaldo Carvalho de Melo <acme@redhat.com> Cc: Borislav Petkov <bp@alien8.de> Cc: Harish Chegondi <harish.chegondi@intel.com> Cc: Jacob Pan <jacob.jun.pan@linux.intel.com> Cc: Jiri Olsa <jolsa@redhat.com> Cc: Kan Liang <kan.liang@intel.com> Cc: Linus Torvalds <torvalds@linux-foundation.org> Cc: Peter Zijlstra <peterz@infradead.org> Cc: Stephane Eranian <eranian@google.com> Cc: Vince Weaver <vincent.weaver@maine.edu> Cc: linux-kernel@vger.kernel.org Link: http://lkml.kernel.org/r/20160222221012.504551295@linutronix.de Signed-off-by: Ingo Molnar <mingo@kernel.org>
Diffstat (limited to 'arch/x86')
-rw-r--r--arch/x86/events/intel/rapl.c42
1 files changed, 23 insertions, 19 deletions
diff --git a/arch/x86/events/intel/rapl.c b/arch/x86/events/intel/rapl.c
index b1d4a2f1feeb..f31e4b417adf 100644
--- a/arch/x86/events/intel/rapl.c
+++ b/arch/x86/events/intel/rapl.c
@@ -44,6 +44,9 @@
* the duration of the measurement. Tools may use a function such as
* ldexp(raw_count, -32);
*/
+
+#define pr_fmt(fmt) "RAPL PMU: " fmt
+
#include <linux/module.h>
#include <linux/slab.h>
#include <linux/perf_event.h>
@@ -144,7 +147,7 @@ static inline u64 rapl_read_counter(struct perf_event *event)
static inline u64 rapl_scale(u64 v, int cfg)
{
if (cfg > NR_RAPL_DOMAINS) {
- pr_warn("invalid domain %d, failed to scale data\n", cfg);
+ pr_warn("Invalid domain %d, failed to scale data\n", cfg);
return v;
}
/*
@@ -680,6 +683,21 @@ static int rapl_check_hw_unit(void (*quirk)(void))
return 0;
}
+static void __init rapl_advertise(void)
+{
+ int i;
+
+ pr_info("API unit is 2^-32 Joules, %d fixed counters, %llu ms ovfl timer\n",
+ hweight32(rapl_cntr_mask), rapl_timer_ms);
+
+ for (i = 0; i < NR_RAPL_DOMAINS; i++) {
+ if (rapl_cntr_mask & (1 << i)) {
+ pr_info("hw unit of domain %s 2^-%d Joules\n",
+ rapl_domain_names[i], rapl_hw_unit[i]);
+ }
+ }
+}
+
static void __init cleanup_rapl_pmus(void)
{
int cpu;
@@ -696,7 +714,7 @@ static const struct x86_cpu_id rapl_cpu_match[] = {
static int __init rapl_pmu_init(void)
{
void (*quirk)(void) = NULL;
- int cpu, ret, i;
+ int cpu, ret;
/*
* check for Intel processor family 6
@@ -751,30 +769,16 @@ static int __init rapl_pmu_init(void)
}
ret = perf_pmu_register(&rapl_pmu_class, "power", -1);
- if (WARN_ON(ret)) {
- pr_info("RAPL PMU detected, registration failed (%d), RAPL PMU disabled\n", ret);
+ if (ret)
goto out;
- }
__perf_cpu_notifier(rapl_cpu_notifier);
cpu_notifier_register_done();
-
- pr_info("RAPL PMU detected,"
- " API unit is 2^-32 Joules,"
- " %d fixed counters"
- " %llu ms ovfl timer\n",
- hweight32(rapl_cntr_mask),
- rapl_timer_ms);
- for (i = 0; i < NR_RAPL_DOMAINS; i++) {
- if (rapl_cntr_mask & (1 << i)) {
- pr_info("hw unit of domain %s 2^-%d Joules\n",
- rapl_domain_names[i], rapl_hw_unit[i]);
- }
- }
-
+ rapl_advertise();
return 0;
out:
+ pr_warn("Initialization failed (%d), disabled\n", ret);
cleanup_rapl_pmus();
cpu_notifier_register_done();
return ret;