diff options
author | Vasu Dev <vasu.dev@intel.com> | 2011-07-27 15:10:39 -0700 |
---|---|---|
committer | James Bottomley <JBottomley@Parallels.com> | 2011-07-28 12:10:35 +0400 |
commit | 324f667833d7ddd9501ed8c0e3ec5754ddb1b695 (patch) | |
tree | 1dbc7ce23d6c8f3c13f6c977d572be90fb95051b /drivers/scsi/libfc | |
parent | 6f06e3a7b2f2d840d42a0c2b9906f444e8f2eba6 (diff) |
[SCSI] libfc, fcoe: ignore rx frame with wrong xid info
Drop the rx frame having xid with wrong cpu info
or received with xid not matching to our xid.
Not dropping such frame is causing panic as
that causes accessing data struct beyond their
bounds.
Signed-off-by: Vasu Dev <vasu.dev@intel.com>
Tested-by: Ross Brattain <ross.b.brattain@intel.com>
Signed-off-by: Robert Love <robert.w.love@intel.com>
Signed-off-by: James Bottomley <JBottomley@Parallels.com>
Diffstat (limited to 'drivers/scsi/libfc')
-rw-r--r-- | drivers/scsi/libfc/fc_exch.c | 4 |
1 files changed, 1 insertions, 3 deletions
diff --git a/drivers/scsi/libfc/fc_exch.c b/drivers/scsi/libfc/fc_exch.c index 7baf2239ce07..01ff082dc34c 100644 --- a/drivers/scsi/libfc/fc_exch.c +++ b/drivers/scsi/libfc/fc_exch.c @@ -802,10 +802,8 @@ static struct fc_exch *fc_exch_find(struct fc_exch_mgr *mp, u16 xid) pool = per_cpu_ptr(mp->pool, xid & fc_cpu_mask); spin_lock_bh(&pool->lock); ep = fc_exch_ptr_get(pool, (xid - mp->min_xid) >> fc_cpu_order); - if (ep) { + if (ep && ep->xid == xid) fc_exch_hold(ep); - WARN_ON(ep->xid != xid); - } spin_unlock_bh(&pool->lock); } return ep; |