summaryrefslogtreecommitdiff
path: root/drivers/s390/block/dasd_3990_erp.c
diff options
context:
space:
mode:
authorStefan Weinhuber <wein@de.ibm.com>2009-12-07 12:51:51 +0100
committerMartin Schwidefsky <sky@mschwide.boeblingen.de.ibm.com>2009-12-07 12:51:34 +0100
commiteb6e199bef288611157b8198c25d12b32bf058d0 (patch)
tree80737a2703a9f4d09cee2410342aeccb281413ae /drivers/s390/block/dasd_3990_erp.c
parent626350b63ef2cd447023d3dc2a34eaa7ca01bfff (diff)
[S390] dasd: improve error recovery for internal I/O
Most of the error conditions reported by a FICON storage server indicate situations which can be recovered. Sometimes the host just needs to retry an I/O request, but sometimes the recovery is more complex and requires the device driver to wait, choose a different path, etc. The DASD device driver has a fully featured error recovery for normal block layer I/O, but not for internal I/O request which are for example used during the device bring up. This can lead to situations where the IPL of a system fails because DASD devices are not properly recognized. This patch will extend the internal I/O handling to use the existing error recovery procedures. Signed-off-by: Stefan Weinhuber <wein@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
Diffstat (limited to 'drivers/s390/block/dasd_3990_erp.c')
-rw-r--r--drivers/s390/block/dasd_3990_erp.c46
1 files changed, 33 insertions, 13 deletions
diff --git a/drivers/s390/block/dasd_3990_erp.c b/drivers/s390/block/dasd_3990_erp.c
index 316eb1256a99..44796ba4eb9b 100644
--- a/drivers/s390/block/dasd_3990_erp.c
+++ b/drivers/s390/block/dasd_3990_erp.c
@@ -69,8 +69,7 @@ dasd_3990_erp_cleanup(struct dasd_ccw_req * erp, char final_status)
* processing until the started timer has expired or an related
* interrupt was received.
*/
-static void
-dasd_3990_erp_block_queue(struct dasd_ccw_req * erp, int expires)
+static void dasd_3990_erp_block_queue(struct dasd_ccw_req *erp, int expires)
{
struct dasd_device *device = erp->startdev;
@@ -80,10 +79,13 @@ dasd_3990_erp_block_queue(struct dasd_ccw_req * erp, int expires)
"blocking request queue for %is", expires/HZ);
spin_lock_irqsave(get_ccwdev_lock(device->cdev), flags);
- device->stopped |= DASD_STOPPED_PENDING;
+ dasd_device_set_stop_bits(device, DASD_STOPPED_PENDING);
spin_unlock_irqrestore(get_ccwdev_lock(device->cdev), flags);
erp->status = DASD_CQR_FILLED;
- dasd_block_set_timer(device->block, expires);
+ if (erp->block)
+ dasd_block_set_timer(erp->block, expires);
+ else
+ dasd_device_set_timer(device, expires);
}
/*
@@ -242,9 +244,13 @@ dasd_3990_erp_DCTL(struct dasd_ccw_req * erp, char modifier)
* DESCRIPTION
* Setup ERP to do the ERP action 1 (see Reference manual).
* Repeat the operation on a different channel path.
- * If all alternate paths have been tried, the request is posted with a
- * permanent error.
- * Note: duplex handling is not implemented (yet).
+ * As deviation from the recommended recovery action, we reset the path mask
+ * after we have tried each path and go through all paths a second time.
+ * This will cover situations where only one path at a time is actually down,
+ * but all paths fail and recover just with the same sequence and timing as
+ * we try to use them (flapping links).
+ * If all alternate paths have been tried twice, the request is posted with
+ * a permanent error.
*
* PARAMETER
* erp pointer to the current ERP
@@ -253,17 +259,25 @@ dasd_3990_erp_DCTL(struct dasd_ccw_req * erp, char modifier)
* erp pointer to the ERP
*
*/
-static struct dasd_ccw_req *
-dasd_3990_erp_action_1(struct dasd_ccw_req * erp)
+static struct dasd_ccw_req *dasd_3990_erp_action_1_sec(struct dasd_ccw_req *erp)
{
+ erp->function = dasd_3990_erp_action_1_sec;
+ dasd_3990_erp_alternate_path(erp);
+ return erp;
+}
+static struct dasd_ccw_req *dasd_3990_erp_action_1(struct dasd_ccw_req *erp)
+{
erp->function = dasd_3990_erp_action_1;
-
dasd_3990_erp_alternate_path(erp);
-
+ if (erp->status == DASD_CQR_FAILED) {
+ erp->status = DASD_CQR_FILLED;
+ erp->retries = 10;
+ erp->lpm = LPM_ANYPATH;
+ erp->function = dasd_3990_erp_action_1_sec;
+ }
return erp;
-
-} /* end dasd_3990_erp_action_1 */
+} /* end dasd_3990_erp_action_1(b) */
/*
* DASD_3990_ERP_ACTION_4
@@ -2294,6 +2308,7 @@ static struct dasd_ccw_req *dasd_3990_erp_add_erp(struct dasd_ccw_req *cqr)
return cqr;
}
+ ccw = cqr->cpaddr;
if (cqr->cpmode == 1) {
/* make a shallow copy of the original tcw but set new tsb */
erp->cpmode = 1;
@@ -2302,6 +2317,9 @@ static struct dasd_ccw_req *dasd_3990_erp_add_erp(struct dasd_ccw_req *cqr)
tsb = (struct tsb *) &tcw[1];
*tcw = *((struct tcw *)cqr->cpaddr);
tcw->tsb = (long)tsb;
+ } else if (ccw->cmd_code == DASD_ECKD_CCW_PSF) {
+ /* PSF cannot be chained from NOOP/TIC */
+ erp->cpaddr = cqr->cpaddr;
} else {
/* initialize request with default TIC to current ERP/CQR */
ccw = erp->cpaddr;
@@ -2486,6 +2504,8 @@ dasd_3990_erp_further_erp(struct dasd_ccw_req *erp)
erp = dasd_3990_erp_action_1(erp);
+ } else if (erp->function == dasd_3990_erp_action_1_sec) {
+ erp = dasd_3990_erp_action_1_sec(erp);
} else if (erp->function == dasd_3990_erp_action_5) {
/* retries have not been successful */