summaryrefslogtreecommitdiff
path: root/drivers/nvme/host
diff options
context:
space:
mode:
authorJens Axboe <axboe@kernel.dk>2019-04-22 09:47:36 -0600
committerJens Axboe <axboe@kernel.dk>2019-04-22 09:47:36 -0600
commit5c61ee2cd5860e41c8ab98837761ffaa93eb4dfe (patch)
tree0c78e25f5020eeee47863092ccbb2a3f56bea8a9 /drivers/nvme/host
parentcdf3e3deb747d5e193dee617ed37c83060eb576f (diff)
parent085b7755808aa11f78ab9377257e1dad2e6fa4bb (diff)
Merge tag 'v5.1-rc6' into for-5.2/block
Pull in v5.1-rc6 to resolve two conflicts. One is in BFQ, in just a comment, and is trivial. The other one is a conflict due to a later fix in the bio multi-page work, and needs a bit more care. * tag 'v5.1-rc6': (770 commits) Linux 5.1-rc6 block: make sure that bvec length can't be overflow block: kill all_q_node in request_queue x86/cpu/intel: Lower the "ENERGY_PERF_BIAS: Set to normal" message's log priority coredump: fix race condition between mmget_not_zero()/get_task_mm() and core dumping mm/kmemleak.c: fix unused-function warning init: initialize jump labels before command line option parsing kernel/watchdog_hld.c: hard lockup message should end with a newline kcov: improve CONFIG_ARCH_HAS_KCOV help text mm: fix inactive list balancing between NUMA nodes and cgroups mm/hotplug: treat CMA pages as unmovable proc: fixup proc-pid-vm test proc: fix map_files test on F29 mm/vmstat.c: fix /proc/vmstat format for CONFIG_DEBUG_TLBFLUSH=y CONFIG_SMP=n mm/memory_hotplug: do not unlock after failing to take the device_hotplug_lock mm: swapoff: shmem_unuse() stop eviction without igrab() mm: swapoff: take notice of completion sooner mm: swapoff: remove too limiting SWAP_UNUSE_MAX_TRIES mm: swapoff: shmem_find_swap_entries() filter out other types slab: store tagged freelist for off-slab slabmgmt ... Signed-off-by: Jens Axboe <axboe@kernel.dk>
Diffstat (limited to 'drivers/nvme/host')
-rw-r--r--drivers/nvme/host/core.c2
-rw-r--r--drivers/nvme/host/fc.c20
2 files changed, 16 insertions, 6 deletions
diff --git a/drivers/nvme/host/core.c b/drivers/nvme/host/core.c
index ddb943395118..248ff3b48041 100644
--- a/drivers/nvme/host/core.c
+++ b/drivers/nvme/host/core.c
@@ -288,7 +288,7 @@ bool nvme_cancel_request(struct request *req, void *data, bool reserved)
"Cancelling I/O %d", req->tag);
nvme_req(req)->status = NVME_SC_ABORT_REQ;
- blk_mq_complete_request(req);
+ blk_mq_complete_request_sync(req);
return true;
}
EXPORT_SYMBOL_GPL(nvme_cancel_request);
diff --git a/drivers/nvme/host/fc.c b/drivers/nvme/host/fc.c
index f3b9d91ba0df..6d8451356eac 100644
--- a/drivers/nvme/host/fc.c
+++ b/drivers/nvme/host/fc.c
@@ -1845,7 +1845,7 @@ nvme_fc_init_queue(struct nvme_fc_ctrl *ctrl, int idx)
memset(queue, 0, sizeof(*queue));
queue->ctrl = ctrl;
queue->qnum = idx;
- atomic_set(&queue->csn, 1);
+ atomic_set(&queue->csn, 0);
queue->dev = ctrl->dev;
if (idx > 0)
@@ -1887,7 +1887,7 @@ nvme_fc_free_queue(struct nvme_fc_queue *queue)
*/
queue->connection_id = 0;
- atomic_set(&queue->csn, 1);
+ atomic_set(&queue->csn, 0);
}
static void
@@ -2183,7 +2183,6 @@ nvme_fc_start_fcp_op(struct nvme_fc_ctrl *ctrl, struct nvme_fc_queue *queue,
{
struct nvme_fc_cmd_iu *cmdiu = &op->cmd_iu;
struct nvme_command *sqe = &cmdiu->sqe;
- u32 csn;
int ret, opstate;
/*
@@ -2198,8 +2197,6 @@ nvme_fc_start_fcp_op(struct nvme_fc_ctrl *ctrl, struct nvme_fc_queue *queue,
/* format the FC-NVME CMD IU and fcp_req */
cmdiu->connection_id = cpu_to_be64(queue->connection_id);
- csn = atomic_inc_return(&queue->csn);
- cmdiu->csn = cpu_to_be32(csn);
cmdiu->data_len = cpu_to_be32(data_len);
switch (io_dir) {
case NVMEFC_FCP_WRITE:
@@ -2257,11 +2254,24 @@ nvme_fc_start_fcp_op(struct nvme_fc_ctrl *ctrl, struct nvme_fc_queue *queue,
if (!(op->flags & FCOP_FLAGS_AEN))
blk_mq_start_request(op->rq);
+ cmdiu->csn = cpu_to_be32(atomic_inc_return(&queue->csn));
ret = ctrl->lport->ops->fcp_io(&ctrl->lport->localport,
&ctrl->rport->remoteport,
queue->lldd_handle, &op->fcp_req);
if (ret) {
+ /*
+ * If the lld fails to send the command is there an issue with
+ * the csn value? If the command that fails is the Connect,
+ * no - as the connection won't be live. If it is a command
+ * post-connect, it's possible a gap in csn may be created.
+ * Does this matter? As Linux initiators don't send fused
+ * commands, no. The gap would exist, but as there's nothing
+ * that depends on csn order to be delivered on the target
+ * side, it shouldn't hurt. It would be difficult for a
+ * target to even detect the csn gap as it has no idea when the
+ * cmd with the csn was supposed to arrive.
+ */
opstate = atomic_xchg(&op->state, FCPOP_STATE_COMPLETE);
__nvme_fc_fcpop_chk_teardowns(ctrl, op, opstate);