diff options
author | majianpeng <majianpeng@gmail.com> | 2012-04-02 01:16:59 +1000 |
---|---|---|
committer | NeilBrown <neilb@suse.de> | 2012-04-03 15:37:38 +1000 |
commit | c6d2e084c7411f61f2b446d94989e5aaf9879b0f (patch) | |
tree | 521616d7bd6ff7eb38217bed1b81c5960fa2023d /drivers/rtc | |
parent | a42f9d83b5c05dc6e678a1f0cd9767502c2c58de (diff) |
md/raid5: Fix a bug about judging if the operation is syncing or replacing
When create a raid5 using assume-clean and echo check or repair to
sync_action.Then component disks did not operated IO but the raid
check/resync faster than normal.
Because the judgement in function analyse_stripe():
if (do_recovery ||
sh->sector >= conf->mddev->recovery_cp)
s->syncing = 1;
else
s->replacing = 1;
When check or repair,the recovery_cp == MaxSectore,so syncing equal zero
not one.
This bug was introduced by commit 9a3e1101b827
md/raid5: detect and handle replacements during recovery.
so this patch is suitable for 3.3-stable.
Cc: stable@vger.kernel.org
Signed-off-by: majianpeng <majianpeng@gmail.com>
Signed-off-by: NeilBrown <neilb@suse.de>
Diffstat (limited to 'drivers/rtc')
0 files changed, 0 insertions, 0 deletions