authorGaetan Nadon <memsize@videotron.ca>2011-01-13 15:14:52 -0500
committerGaetan Nadon <memsize@videotron.ca>2011-01-13 15:14:52 -0500
commit379b0529eca8cc808c31e21afe041e36ffe82469 (patch)
tree02c2f624146a81abd93a0a3a8342f6207f1c1ac1 /man
parenta298bf274a53c1c04b6b634b7e5bfb1f6ff62089 (diff)
config: move man pages into their own directory
Use services provided by XORG_MANPAGE_SECTIONS. Use standard Makefile for man pages. Signed-off-by: Gaetan Nadon <memsize@videotron.ca>
Diffstat (limited to 'man')
-rw-r--r--man/Makefile.am12
-rw-r--r--man/xscope.man197
2 files changed, 209 insertions, 0 deletions
diff --git a/man/Makefile.am b/man/Makefile.am
new file mode 100644
index 0000000..ed23ba2
--- /dev/null
+++ b/man/Makefile.am
@@ -0,0 +1,12 @@
+
+appmandir = $(APP_MAN_DIR)
+appman_PRE = xscope.man
+appman_DATA = $(appman_PRE:man=$(APP_MAN_SUFFIX))
+
+EXTRA_DIST = $(appman_PRE)
+CLEANFILES = $(appman_DATA)
+SUFFIXES = .$(APP_MAN_SUFFIX) .man
+
+# String replacements in MAN_SUBSTS now come from xorg-macros.m4 via configure
+.man.$(APP_MAN_SUFFIX):
+ $(AM_V_GEN)$(SED) $(MAN_SUBSTS) < $< > $@
diff --git a/man/xscope.man b/man/xscope.man
new file mode 100644
index 0000000..f6ae899
--- /dev/null
+++ b/man/xscope.man
@@ -0,0 +1,197 @@
+.TH XSCOPE 1 __xorgversion__
+.SH NAME
+xscope - X Window Protocol Viewer
+.SH SYNOPSIS
+.B xscope
+[\fB-i\fP\fI<in-port>\fP] [\fB-o\fP\fI<out-port>\fP]
+[\fB-h\fP\fI<server-host>\fP] [\fB-d\fP\fI<display-number>\fP]
+[\fB-q\fP] [\fB-v\fP\fI<n>\fP] [\fB-r\fP]
+[\fB-D\fP\fI<debug-level>\fP] [\fB-S\fP\fI<n>\fP] [\fB-t\fP]
+.SH DESCRIPTION
+.I Xscope
+sits in-between an X11 client and an X11 server and prints the contents
+of each request, reply, error, or event that is communicated between them.
+.I Xscope
+can decode the core X11 protocol and several extensions, including
+BIG-REQUESTS, LBX, MIT-SHM, NCD-WinCenterPro, RANDR, and RENDER.
+This information can be useful in debugging and performance
+tuning of X11 servers and clients.
+.PP
+To operate, \fIxscope\fP must know the host, port, and display to use
+to connect to the X11 server. In addition, it must know the port on
+which it should listen for X11 clients. Two cases are common:
+.PP
+.TP 5
+(1) The X11 server is on the same host as \fIxscope\fP.
+In this case, the input port for \fIxscope\fP should be selected as an
+X11 server on a different display, and the client DISPLAY argument
+adjusted to select \fIxscope\fP . For example, if the X11 server is
+on port 6001, display 1, then \fIxscope\fP can use port 6002 as its
+input port. The client can use display 1 for direct access to X11 or
+display 2 for access to \fIxscope\fP.
+.PP
+.TP 5
+(2) The X11 server is on a different host than \fIxscope\fP.
+In this case the same input and output ports can be used, and the host
+component of the DISPLAY is used to select \fIxscope\fP or X11.
+.SH ARGUMENTS
+.PP
+.TP 10
+.BI \-i <input-port>
+Specify the port that \fIxscope\fP will use to take requests from clients
+(defaults to 1).
+For X11, this port is automatically biased by 6000.
+.PP
+.TP 10
+.BI \-o <output-port>
+Determines the port that
+\fIxscope\fP will use to connect to X11 (defaults to 0).
+For X11, this port is automatically biased by 6000.
+.PP
+.TP 10
+.BI \-h <host>
+Determines the host that \fIxscope\fP will use to find its X11 server.
+.PP
+.TP 10
+.BI \-d <display>
+Defines the display number. The display number is added to the input
+and output port to give the actual ports which are used by \fIxscope\fP.
+.PP
+.TP 10
+.B \-q
+Quiet output mode. Gives only the names of requests, replies, errors, and
+events, but does not indicate contents.
+.PP
+.TP 10
+.BI \-v <print-level>
+Determines the level of printing which \fIxscope\fP will provide. The
+print-level can be 0 (same as quiet mode), 1, 2, 3, 4. The larger
+numbers give more and more output. For example, a successful setup
+returns a string which is the name of the vendor of the X11 server.
+At level 1, the explicit field giving the length of the string is
+suppressed since it can be inferred from the string. At level 2 and
+above the length is explicitly printed.
+.PP
+.TP 10
+.B -r
+Print only raw data without decoding it.
+.PP
+.TP 10
+.BI -D <debug-level>
+Print debugging information at the specified level.
+.PP
+.TP 10
+.BI -S <n>
+Toggle output on or off when SIGUSR1 is received. If \fIn\fP is 0,
+the initial state is off. If \fIn\fP is 1, the initial state is on.
+.PP
+.TP 10
+.B -t
+Terminate \fIxscope\fP when all clients close.
+.SH INTERACTIVE MODE
+.PP
+When \fBxscope\fP receives an interrupt signal (normally generated by
+Control-C) it enters an interactive mode in which it prompts for commands.
+Available commands in this mode are:
+.TP 10
+.B audio, a
+Show current verbosity level for NAS protocol packets.
+.TP 10
+\fBaudio\fP \fIn\fP, \fBa\fP \fIn\fP
+Set current verbosity level for NAS protocol packets to \fIn\fP.
+.TP 10
+.B break, b
+List currently defined breakpoints.
+.TP 10
+\fBbreak\fP \fIrequest...\fP, \fBb\fP \fIrequest...\fP
+Create a breakpoint for the specified protocol requests. The breakpoint
+will be enabled by default. When the breakpoint is enabled, \fBxscope\fP
+will stop for interactive commands after processing a request of the
+specified type. Requests and extensions may be specified by name or number.
+If an extension is followed by a ":" and a number, it will only
+break for the specified minor opcode for that extension. Note that since
+extension opcodes are not known until the extension is first seen, breakpoints
+cannot currently be set on extensions until after a QueryExtension request
+and reply are processed for that extension, so users may need to initially
+set a breakpoint on QueryExtension, and after processing that set the
+breakpoint for the target extension.
+.TP 10
+.B cont, c
+Resume processing of data passing between server and clients.
+.TP 10
+.B delete, del
+Delete all breakpoints.
+.TP 10
+\fBdelete\fP \fIbreakpoint...\fP, \fBdel\fP \fIbreakpoint...\fP
+Delete listed breakpoints, specified by number.
+.TP 10
+.B disable, d
+Disable all breakpoints.
+.TP 10
+\fBdisable\fP \fIbreakpoint...\fP, \fBd\fP \fIbreakpoint...\fP
+Disable listed breakpoints, specified by number.
+.TP 10
+.B enable, e
+Enable all breakpoints.
+.TP 10
+\fBenable\fP \fIbreakpoint...\fP, \fBe\fP \fIbreakpoint...\fP
+Enable listed breakpoints, specified by number.
+.TP 10
+.B help, ?
+Print list of available commands.
+.TP 10
+\fBhelp\fP \fIcommand...\fP, \fB?\fP \fIcommand...\fP
+Describe specified command or commands.
+.TP 10
+.B level, l
+Show current verbosity level for X11 protocol packets.
+.TP 10
+\fBlevel\fP \fIn\fP, \fBl\fP \fIn\fP
+Set current verbosity level for X11 protocol packets to \fIn\fP.
+.TP 10
+.B quit, q
+Quit \fBxscope\fP.
+.TP 10
+.B step, s
+Process one request, then prompt for another command.
+.SH EXAMPLES
+.LP
+xscope -v4 -hcleo -d0 -o0 -i1
+.PP
+This command would have xscope communicate with an X11 server on host
+``cleo'', display 0; xscope itself would be available on the current
+host as display 1 (display of 0 plus the 1 of -i1). Verbose level 4.
+.LP
+xscope -q -d1 -o1 -o3
+.PP
+The X11 server for the current host, display 2 (1 for -d1 plus 1 for -o1)
+would be used by xscope which would run as display 4 (1 for -d1 plus 3 for
+-o3). Quiet mode (verbose level 0).
+.SH SEE ALSO
+.BR X (__miscmansuffix__),
+.BR Xsecurity (__miscmansuffix__),
+X11 Protocol and extension protocol documents
+.SH AUTHOR
+.PP
+James L. Peterson (MCC)
+.PP
+Copyright (C) 1988 MCC
+.PP
+Permission to use, copy, modify, distribute, and sell this software and its
+documentation for any purpose is hereby granted without fee, provided that
+the above copyright notice appear in all copies and that both that
+copyright notice and this permission notice appear in supporting
+documentation, and that the name of MCC not be used in
+advertising or publicity pertaining to distribution of the software without
+specific, written prior permission. MCC makes no
+representations about the suitability of this software for any purpose. It
+is provided "as is" without express or implied warranty.
+.PP
+MCC DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS SOFTWARE,
+INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS, IN NO
+EVENT SHALL MCC BE LIABLE FOR ANY SPECIAL, INDIRECT OR
+CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF USE,
+DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR OTHER
+TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR
+PERFORMANCE OF THIS SOFTWARE.
+