summaryrefslogtreecommitdiff
path: root/xc/unsupported/doc/PHIGS/man3/p085
blob: 6bc6c0838daeee9994e0ed43abc4fb076be7e918 (plain)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
96
97
98
99
100
101
102
103
104
105
106
107
108
109
110
111
112
113
114
115
116
117
118
119
120
121
122
123
124
125
126
127
128
129
130
131
132
133
134
135
136
137
138
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
155
156
157
158
159
160
161
162
163
164
165
166
167
168
169
170
171
172
173
174
175
176
177
178
179
180
181
182
183
184
185
186
187
188
189
190
191
192
193
194
195
196
197
198
199
200
201
202
203
204
205
206
207
208
209
210
211
212
213
214
215
216
217
218
219
220
221
222
223
224
225
226
227
228
229
230
231
232
233
234
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
251
252
253
254
255
256
257
258
259
260
261
262
263
264
265
266
267
268
269
270
271
272
273
274
275
276
277
278
279
280
281
282
283
284
285
286
287
288
289
290
291
292
293
294
295
296
297
298
299
300
301
302
303
304
305
306
307
.\"
.\" $XConsortium: p085,v 5.1 91/02/16 09:38:16 rws Exp $
.\"
.\" 
$XMCOPY
.\" Copyright (c) 1990, 1991 by Sun Microsystems, Inc. and the X Consortium.
.\" 
.\"                         All Rights Reserved
.\" 
.\" Permission to use, copy, modify, and distribute this software and its 
.\" documentation for any purpose and without fee is hereby granted, 
.\" provided that the above copyright notice appear in all copies and that
.\" both that copyright notice and this permission notice appear in 
.\" supporting documentation, and that the names of Sun Microsystems,
.\" and the X Consortium not be used in advertising or publicity 
.\" pertaining to distribution of the software without specific, written 
.\" prior permission.  
.\" 
.\" SUN MICROSYSTEMS DISCLAIMS ALL WARRANTIES WITH REGARD TO THIS SOFTWARE, 
.\" INCLUDING ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS, IN NO
.\" EVENT SHALL SUN MICROSYSTEMS BE LIABLE FOR ANY SPECIAL, INDIRECT OR
.\" CONSEQUENTIAL DAMAGES OR ANY DAMAGES WHATSOEVER RESULTING FROM LOSS OF
.\" USE, DATA OR PROFITS, WHETHER IN AN ACTION OF CONTRACT, NEGLIGENCE OR
.\" OTHER TORTIOUS ACTION, ARISING OUT OF OR IN CONNECTION WITH THE USE OR
.\" PERFORMANCE OF THIS SOFTWARE.
.TH "INITIALIZE VALUATOR" 3P "29 February 1991"
.SH NAME
INITIALIZE VALUATOR \- initialize a valuator input device
using \s-2\&2D\s+2 data 
.IX "Valuator Input Devices" "INITIALIZE VALUATOR"
.SH SYNOPSIS
.SS C Syntax
.ft B
.ta 1.25i 3.25i
.nf
void
pinit_val ( ws, dev, init, pet, echo_area, record )
Pint	ws;	\fIworkstation identifier\fP
Pint	dev;	\fIvaluator device number\fP
Pfloat	init;	\fIinitial value\fP
Pint	pet;	\fIprompt and echo type\fP
Plimit	*echo_area;	\fIecho area pointer\fP
Pval_data	*record;	\fIdata record pointer\fP
.fi
.ft R
.SS Required PHIGS Operating States
(PHOP, WSOP, *, *)
.SH DESCRIPTION
.SS Purpose
Use \s-2INITIALIZE VALUATOR\s+2 to set the initialization parameters of a
\s-2VALUATOR\s+2 device.
This function stores these parameters in the workstation state list
of the workstation associated with the specified device.
The specified \fBdevice must be in \s-2REQUEST\s+2 mode\fP when this
function is called.
.SS C Input Parameters
.IP \fIws\fP
The workstation identifier of the workstation associated with the device.
.IP \fIdev\fP
The device number of the \s-2VALUATOR\s+2 device to initialize.
See the \fIAVAILABLE DEVICES\fP section below for a description of the
available devices.
.IP \fIinit\fP
The initial valuator value.
.IP \fIpet\fP
The prompt/echo type desired.
Those supported by each device are listed in the
\fIAVAILABLE DEVICES\fP section below.
.IP \fIecho_area\fP
A pointer to a Plimit structure defining the
\fIx\fP and \fIy\fP
components of the echo volume, in Device Coordinates (\s-2DC\s+2).  
The existing \fIz\fP component in the workstation state list is left unchanged.
Plimit is defined in phigs.h as follows:
.\" Plimit
.sp .4
.ta .5i +1i  +1i
.nf
typedef struct {
.sp .2
	Pfloat	x_min;	/* minimum x coordinate value */
	Pfloat	x_max;	/* maximum x coordinate value */
	Pfloat	y_min;	/* minimum y coordinate value */
	Pfloat	y_max;	/* maximum y coordinate value */
.sp .2
} Plimit;
.fi
.IP \fIrecord\fP
A pointer to a Pval_data structure containing the data record information.
The contents of the data record for each device and prompt/echo type are
described below in the \fIAvailable Devices\fP section.
.IP
Some members of the data record correspond to the prompt/echo type
being used.
As an example, the appropriate member of the Pval_data structure for
prompt/echo type 1 is
\fIpet_r1\fP.
.IP
For some prompt/echo types the data record is not used.
The \fIrecord\fP parameter, however, must still be passed.
.IP
Pval_data is defined in phigs.h as:
.bp
.ta .5i +1.5i  +1.25i
.nf
typedef struct {
.sp .2
	Pfloat	low;            /* low range limit */
	Pfloat	high;           /* high range limit */
	union {
	    struct {
	          Pint	unused;
	    } pet_r1;
	    struct {
	          Pchar	*label;	/* the device label widget string */
	          Pchar	*format;	/* the current value widget format string */
	          Pchar	*low_label;	/* the low value widget format string */
	          Pchar	*high_label;	/* the low value widget format string */
	    } pet_u1;
	} pets;
.sp .2
} Pval_data;
.fi
.SS Execution
.LP
\s-2INITIALIZE VALUATOR\s+2 sets the initialization parameters of a
\s-2VALUATOR\s+2 device.
This function stores these parameters in the workstation state list
of the workstation associated with the specified device.
The specified device must be in \s-2REQUEST\s+2 mode when this
function is called.
.LP
The parameters that are initialized by this function are 
\fIinitial value\fP,
\fIprompt/echo type\fP,
\fIecho volume\fP,
and
\fIinput data record\fP.
.LP
The \fIinitial value\fP is the logical input value the device will take on
whenever it is enabled.
The device's measure will retain this value until operator input changes it.
A device is enabled when the appropriate \s-2REQUEST\s+2 function is called,
or when its input mode is set to \s-2SAMPLE\s+2 or \s-2EVENT\s+2.
.LP
A \s-2VALUATOR\s+2 device measure consists of a floating point number.
This number is between the device's low value and high value, inclusive.
.LP
The \fIprompt/echo type\fP determines how the device will be presented to
the operator and respond to his actions.  
Each device supports one or more prompt/echo types.  
Those supported by each device are listed in the device's
description in the \fIAVAILABLE DEVICES\fP section below.  
All devices support prompt/echo type 1.  
Positive prompt/echo types are defined by the \s-2PHIGS\s+2 standard.  
Negative types are implementation-dependent.  
.LP
The \fIecho volume\fP defines the region of the display surface in which to
echo the device.  It is specified in \s-2DC\s+2.  
Devices that use the echo volume may restrict their display to this region.  
Some of these devices may still recognize operator input
outside the region even though they do not display there.  
This function specifies only the \fIx\fP and \fIy\fP components of the echo volume.  
The existing \fIz\fP component in the workstation state list is left unchanged.
.LP
The \fIinput data record\fP contains the prompt/echo type specific
information that controls the device's appearance and characteristics.
Not all of the data record contents are used by some devices.
The device descriptions in the \fIAVAILABLE DEVICES\fP section below
list the data record contents that each device recognizes.
.LP
All the initialization parameters must be specified properly,
or this function will generate an error.
The \s-2\fIERRORS\fP\s+2 section below lists the possible error conditions.
.LP
The default initialization parameters and the list of prompt/echo types
supported by a \s-2VALUATOR\s+2 input device can be inquired with the function
\s-2INQUIRE DEFAULT VALUATOR DEVICE DATA\s+2.
The current state of the device can be inquired with the function
\s-2INQUIRE VALUATOR DEVICE STATE\s+2.
.SH AVAILABLE DEVICES
.SS Device 1 - "Athena Scrollbar Widget"
.LP
The valuator device realization is a collection of widgets from the Athena 
widget set. It consists of a Shell widget, a Pane widget, 4 Label widgets 
and a Scrollbar widget. The Scrollbar is the item manipulated by the 
operator to change the valuator value. The four Label widgets display 
a label for the device and labels for each of the current value, low
value and high value of the device. The device label, current value 
and low value are all displayed (by default) to the left of the Scrollbar. 
The high value is displayed to the right. The Pane, Label, and Scrollbar 
widgets are children of the Shell widget.
.LP
Each of the four Label widgets has a character string associated with it
that indicates what to display in that widget.  The strings for the
current value, low value and high value widgets may contain printf(3)
format descriptors.  \s-2PEX-SI\s+2 will expand these descriptors with the
corresponding device value so that the value appears in the widget.
For example, if the low value widget string is ``the low value is %f'' and
the low value is 5, \s-2PEX-SI\s+2 will display the widget as ``the low value is 5.0''.
.LP
The echo volume is not used for this device.
.LP
\fBPrompt/echo types supported\fP: 1, -1
.IP "PET 1" .8i
Display the valuator item as specified above.
The string for the label widget is ``value.''
The strings for the current value, low value, and high value strings are all \fI%8.3g\fP.
(Use \s-2PET -1\s+2 if these values are not as desired.)
No data record is used with \s-2PET 1\s+2.
.IP "PET -1"
Display the valuator item as specified for \s-2PET 1\s+2
but with application-specified widget strings.
The label, low value, and high value strings are specified in the data record.
.LP
The widgets used and their names, in decreasing hierarchy, are:
.IP
valuator1 \(-> \fIapplicationShellWidgetClass\fR
.RS
.br
pane \(-> \fIpanedWidgetClass\fR
.RS
.br
label \(-> \fIlabelWidgetClass\fR
.br
readout \(-> \fIlabelWidgetClass\fR
.br
low_label \(-> \fIlabelWidgetClass\fR
.br
scrollbar \(-> \fIscrollbarWidgetClass\fR
.br
high_label \(-> \fIlabelWidgetClass\fR
.br
.RE
.RE
.LP
Fallback resources for valuator devices are specified in the \s-1API\s+1.  They
are:
.IP
*valuator1.pane.orientation \(-> \fIhorizontal\fR
.IP
*valuator1*scrollbar.orientation \(-> \fIhorizontal\fR
.IP
*valuator1*scrollbar.length \(-> \fI50\fR
.IP
*valuator1*scrollbar.translations \(em
.RS
.br
<Btn1Down> \(-> \fIStartScroll(Continuous) MoveThumb() NotifyThumb()\fR
.br
<Btn1Motion> \(-> \fIMoveThumb() NotifyThumb()\fR 
.br
<Btn1Up> \(-> \fINotifyScroll(Proportional) RequestSatisfied()  EndScroll()\fR
.RE
.IP
*valuator1*scrollbar.skipAdjust \(-> \fI\s-1FALSE\s+1\fR
.IP
*valuator1*skipAdjust \(-> \fI\s-1TRUE\s+1\fR
.IP
*valuator1*showGrip \(-> \fI\s-1FALSE\s+1\fR
.LP
The fully qualified name of all widgets is
<appl_name>.workstation<ws_id>.valuator<dev_id>.<widget_name>, where
<appl_name> is the application name specified in the call to OPEN XPHIGS.
(This will be "phigs" if OPEN XPHIGS was not called.)
For example, phigs.workstation1.valuator1.pane is the name of the
pane widget of valuator device 1 on workstation 1.
.SH ERRORS
.IP 003
Ignoring function, function requires state 
(\s-2PHOP\s+2, \s-2WSOP\s+2, \s-2*\s+2, \s-2*\s+2)
.IP 054
Ignoring function, the specified workstation is not open
.IP 061
Ignoring function, specified workstation is neither of category \s-2INPUT\s+2
nor of category \s-2OUTIN\s+2
.IP 250
Ignoring function, the specified device is not available
on the specified workstation
.IP 251
Ignoring function, the function requires the input device to be in \s-2REQUEST\s+2 mode
.IP 253
Warning, the specified prompt/echo type is not available on the specified
workstation.
Prompt/echo type one will be used in its place
.IP 254
Ignoring function, invalid echo area/volume;
\s-2XMIN \(>= XMAX, YMIN \(>= YMAX, or ZMIN > ZMAX\s+2
.IP 255
Ignoring function, one of the echo area/volume boundary points
is outside the range of the device
.IP 260
Ignoring function, one of the fields within the input device data record
is in error
.IP 261
Ignoring function, initial value is invalid
.SH SEE ALSO
.nf
.IP
.ta 0.5i
.SM "SET VALUATOR MODE (3P)"
.SM "REQUEST VALUATOR (3P)"
.SM "SAMPLE VALUATOR (3P)"
.SM "GET VALUATOR (3P)"
.SM "INQUIRE VALUATOR DEVICE STATE (3P)"
.SM "INITIALIZE VALUATOR 3 (3P)"
.fi