diff options
author | Rodrigo Siqueira <Rodrigo.Siqueira@amd.com> | 2020-09-30 13:57:54 -0400 |
---|---|---|
committer | Rodrigo Siqueira <Rodrigo.Siqueira@amd.com> | 2020-10-09 12:20:45 -0400 |
commit | 3d7289e2bc4d4c10cdd7dbe9f814166587daf5a2 (patch) | |
tree | 19c73b72e7b574111a6c485dac90ae736a6c7211 | |
parent | 74c3d54f066d595dbbbf4c920c8f68af702f1324 (diff) |
drm/amd/display: Avoid set zero in the requested clk
Sometimes CRTCs can be disabled due to display unplugging or temporarily
transition in the userspace; in these circumstances, DCE tries to set
the minimum clock threshold. When we have this situation, the function
bw_calcs is invoked with number_of_displays set to zero, making DCE set
dispclk_khz and sclk_khz to zero. For these reasons, we have seen some
ATOM bios errors that look like:
[drm:atom_op_jump [amdgpu]] *ERROR* atombios stuck in loop for more than
5secs aborting
[drm:amdgpu_atom_execute_table_locked [amdgpu]] *ERROR* atombios stuck
executing EA8A (len 761, WS 0, PS 0) @ 0xEABA
This error happens due to an attempt to optimize the bandwidth using the
sclk, and the dispclk clock set to zero. Technically we handle this in
the function dce112_set_clock, but we are not considering the case that
this value is set to zero. This commit fixes this issue by ensuring that
we never set a minimum value below the minimum clock threshold.
Acked-by: Alex Deucher <alexander.deucher@amd.com>
Reviewed-by: Nicholas Kazlauskas <nicholas.kazlauskas@amd.com>
Signed-off-by: Rodrigo Siqueira <Rodrigo.Siqueira@amd.com>
-rw-r--r-- | drivers/gpu/drm/amd/display/dc/clk_mgr/dce112/dce112_clk_mgr.c | 3 |
1 files changed, 1 insertions, 2 deletions
diff --git a/drivers/gpu/drm/amd/display/dc/clk_mgr/dce112/dce112_clk_mgr.c b/drivers/gpu/drm/amd/display/dc/clk_mgr/dce112/dce112_clk_mgr.c index d031bd3d3072..807dca8f7d7a 100644 --- a/drivers/gpu/drm/amd/display/dc/clk_mgr/dce112/dce112_clk_mgr.c +++ b/drivers/gpu/drm/amd/display/dc/clk_mgr/dce112/dce112_clk_mgr.c @@ -79,8 +79,7 @@ int dce112_set_clock(struct clk_mgr *clk_mgr_base, int requested_clk_khz) memset(&dce_clk_params, 0, sizeof(dce_clk_params)); /* Make sure requested clock isn't lower than minimum threshold*/ - if (requested_clk_khz > 0) - requested_clk_khz = max(requested_clk_khz, + requested_clk_khz = max(requested_clk_khz, clk_mgr_dce->base.dentist_vco_freq_khz / 62); dce_clk_params.target_clock_frequency = requested_clk_khz; |