power: supply: axp288_fuel_gauge: Only read PWR_OP_MODE, FG_LOW_CAP_REG regs once
Accessing registers on the AXP288 is quite expensive, so we should avoid
doing unnecessary accesses.
The FG_LOW_CAP_REG never changes underneath us, so we only need to read
it once. Devices with an AXP288 do not have user-replace (let alone
hot-swappable) batteries and the only bit we care about in the
PWR_OP_MODE register is the CHRG_STAT_BAT_PRESENT bit, so we can get
away with only reading the PWR_OP_MODE register once too.
Note that the FG_LOW_CAP_REG is not marked volatile in the regmap, so we
were effectively already reading it once. This change makes this explicit,
this is done as preparation of a further patch which moves all remaining
register accesses in fuel_gauge_get_property() out of that function.
Signed-off-by: Hans de Goede <hdegoede@redhat.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
Diffstat (limited to 'drivers/power')
-rw-r--r-- | drivers/power/supply/axp288_fuel_gauge.c | 37 |
1 files changed, 21 insertions, 16 deletions
diff --git a/drivers/power/supply/axp288_fuel_gauge.c b/drivers/power/supply/axp288_fuel_gauge.c index 1366027edf49..8011628d3704 100644 --- a/drivers/power/supply/axp288_fuel_gauge.c +++ b/drivers/power/supply/axp288_fuel_gauge.c @@ -111,6 +111,8 @@ struct axp288_fg_info { struct mutex lock; int status; int max_volt; + int pwr_op; + int low_cap; struct dentry *debug_file; }; @@ -336,11 +338,7 @@ static int fuel_gauge_get_property(struct power_supply *ps, val->intval = PROP_CURR(value); break; case POWER_SUPPLY_PROP_PRESENT: - ret = fuel_gauge_reg_readb(info, AXP20X_PWR_OP_MODE); - if (ret < 0) - goto fuel_gauge_read_err; - - if (ret & CHRG_STAT_BAT_PRESENT) + if (info->pwr_op & CHRG_STAT_BAT_PRESENT) val->intval = 1; else val->intval = 0; @@ -355,10 +353,7 @@ static int fuel_gauge_get_property(struct power_supply *ps, val->intval = (ret & FG_REP_CAP_VAL_MASK); break; case POWER_SUPPLY_PROP_CAPACITY_ALERT_MIN: - ret = fuel_gauge_reg_readb(info, AXP288_FG_LOW_CAP_REG); - if (ret < 0) - goto fuel_gauge_read_err; - val->intval = (ret & 0x0f); + val->intval = (info->low_cap & 0x0f); break; case POWER_SUPPLY_PROP_TECHNOLOGY: val->intval = POWER_SUPPLY_TECHNOLOGY_LION; @@ -398,7 +393,7 @@ static int fuel_gauge_set_property(struct power_supply *ps, const union power_supply_propval *val) { struct axp288_fg_info *info = power_supply_get_drvdata(ps); - int ret = 0; + int new_low_cap, ret = 0; mutex_lock(&info->lock); switch (prop) { @@ -407,12 +402,12 @@ static int fuel_gauge_set_property(struct power_supply *ps, ret = -EINVAL; break; } - ret = fuel_gauge_reg_readb(info, AXP288_FG_LOW_CAP_REG); - if (ret < 0) - break; - ret &= 0xf0; - ret |= (val->intval & 0xf); - ret = fuel_gauge_reg_writeb(info, AXP288_FG_LOW_CAP_REG, ret); + new_low_cap = info->low_cap; + new_low_cap &= 0xf0; + new_low_cap |= (val->intval & 0xf); + ret = fuel_gauge_reg_writeb(info, AXP288_FG_LOW_CAP_REG, new_low_cap); + if (ret == 0) + info->low_cap = new_low_cap; break; default: ret = -EINVAL; @@ -695,6 +690,16 @@ static int axp288_fuel_gauge_probe(struct platform_device *pdev) break; } + ret = fuel_gauge_reg_readb(info, AXP20X_PWR_OP_MODE); + if (ret < 0) + goto out_free_iio_chan; + info->pwr_op = ret; + + ret = fuel_gauge_reg_readb(info, AXP288_FG_LOW_CAP_REG); + if (ret < 0) + goto out_free_iio_chan; + info->low_cap = ret; + psy_cfg.drv_data = info; info->bat = power_supply_register(&pdev->dev, &fuel_gauge_desc, &psy_cfg); if (IS_ERR(info->bat)) { |