summaryrefslogtreecommitdiff
path: root/security
diff options
context:
space:
mode:
authorChris Packham <chris.packham@alliedtelesis.co.nz>2017-04-22 07:08:09 +1200
committerGuenter Roeck <linux@roeck-us.net>2017-04-21 12:33:57 -0700
commit4abdf38d206fdc22f7a3f7bf79eef78734ec84ab (patch)
tree761de2127e29bd13ec0511a53cd08dda4a9168a1 /security
parentbdaf9c40b2d1d67617b259c59ce1858eda54b4ce (diff)
hwmon: (adt7475) set start bit in probe
The ADT7475 and ADT7476 have the STRT bit cleared by default[1]. Before any monitoring activities the STRT bit needs to be set. Logically this needs to happen before any of the sensors are read so the probe() function seems the best place for it. [1] - https://www.onsemi.com/pub/Collateral/ADT7475-D.PDF Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
Diffstat (limited to 'security')