author | Linus Torvalds <torvalds@linux-foundation.org> | 2017-07-14 13:12:32 -0700 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2017-07-14 13:12:32 -0700 |
commit | 4d25ec19669292a65a32498eabdabdd32b1a8747 (patch) | |
tree | c05bcadf3c4f24dedac48a3256add87a5af7655e /include | |
parent | 907afe5923b4f89b3c377e8ce3b495124321659c (diff) | |
parent | 5d72ed35678a351a1aed4b454c25d583f8bccb28 (diff) |
Merge branch 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux
Pull thermal management updates from Zhang Rui:
- Improve thermal cpu_cooling interaction with cpufreq core.
The cpu_cooling driver is designed to use CPU frequency scaling to
avoid high thermal states for a platform. But it wasn't glued really
well with cpufreq core.
For example clipped-cpus is copied from the policy structure and its
much better to use the policy->cpus (or related_cpus) fields directly
as they may have got updated. Not that things were broken before this
series, but they can be optimized a bit more.
This series tries to improve interactions between cpufreq core and
cpu_cooling driver and does some fixes/cleanups to the cpu_cooling
driver. (Viresh Kumar)
- A couple of fixes and cleanups in thermal core and imx, hisilicon,
bcm_2835, int340x thermal drivers. (Arvind Yadav, Dan Carpenter,
Sumeet Pawnikar, Srinivas Pandruvada, Willy WOLFF)
* 'next' of git://git.kernel.org/pub/scm/linux/kernel/git/rzhang/linux: (24 commits)
thermal: bcm2835: fix an error code in probe()
thermal: hisilicon: Handle return value of clk_prepare_enable
thermal: imx: Handle return value of clk_prepare_enable
thermal: int340x: check for sensor when PTYP is missing
Thermal/int340x: Fix few typos and kernel-doc style
thermal: fix source code documentation for parameters
thermal: cpu_cooling: Replace kmalloc with kmalloc_array
thermal: cpu_cooling: Rearrange struct cpufreq_cooling_device
thermal: cpu_cooling: 'freq' can't be zero in cpufreq_state2power()
thermal: cpu_cooling: don't store cpu_dev in cpufreq_cdev
thermal: cpu_cooling: get_level() can't fail
thermal: cpu_cooling: create structure for idle time stats
thermal: cpu_cooling: merge frequency and power tables
thermal: cpu_cooling: get rid of 'allowed_cpus'
thermal: cpu_cooling: OPPs are registered for all CPUs
thermal: cpu_cooling: store cpufreq policy
cpufreq: create cpufreq_table_count_valid_entries()
thermal: cpu_cooling: use cpufreq_policy to register cooling device
thermal: cpu_cooling: get rid of a variable in cpufreq_set_cur_state()
thermal: cpu_cooling: remove cpufreq_cooling_get_level()
...
Diffstat (limited to 'include')
-rw-r--r-- | include/linux/cpu_cooling.h | 32 | ||||
-rw-r--r-- | include/linux/cpufreq.h | 14 |
2 files changed, 28 insertions, 18 deletions
diff --git a/include/linux/cpu_cooling.h b/include/linux/cpu_cooling.h index c156f5082758..d4292ebc5c8b 100644 --- a/include/linux/cpu_cooling.h +++ b/include/linux/cpu_cooling.h @@ -28,47 +28,49 @@ #include <linux/thermal.h> #include <linux/cpumask.h> +struct cpufreq_policy; + typedef int (*get_static_t)(cpumask_t *cpumask, int interval, unsigned long voltage, u32 *power); #ifdef CONFIG_CPU_THERMAL /** * cpufreq_cooling_register - function to create cpufreq cooling device. - * @clip_cpus: cpumask of cpus where the frequency constraints will happen + * @policy: cpufreq policy. */ struct thermal_cooling_device * -cpufreq_cooling_register(const struct cpumask *clip_cpus); +cpufreq_cooling_register(struct cpufreq_policy *policy); struct thermal_cooling_device * -cpufreq_power_cooling_register(const struct cpumask *clip_cpus, +cpufreq_power_cooling_register(struct cpufreq_policy *policy, u32 capacitance, get_static_t plat_static_func); /** * of_cpufreq_cooling_register - create cpufreq cooling device based on DT. * @np: a valid struct device_node to the cooling device device tree node. - * @clip_cpus: cpumask of cpus where the frequency constraints will happen + * @policy: cpufreq policy. */ #ifdef CONFIG_THERMAL_OF struct thermal_cooling_device * of_cpufreq_cooling_register(struct device_node *np, - const struct cpumask *clip_cpus); + struct cpufreq_policy *policy); struct thermal_cooling_device * of_cpufreq_power_cooling_register(struct device_node *np, - const struct cpumask *clip_cpus, + struct cpufreq_policy *policy, u32 capacitance, get_static_t plat_static_func); #else static inline struct thermal_cooling_device * of_cpufreq_cooling_register(struct device_node *np, - const struct cpumask *clip_cpus) + struct cpufreq_policy *policy) { return ERR_PTR(-ENOSYS); } static inline struct thermal_cooling_device * of_cpufreq_power_cooling_register(struct device_node *np, - const struct cpumask *clip_cpus, + struct cpufreq_policy *policy, u32 capacitance, get_static_t plat_static_func) { @@ -82,15 +84,14 @@ of_cpufreq_power_cooling_register(struct device_node *np, */ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev); -unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq); #else /* !CONFIG_CPU_THERMAL */ static inline struct thermal_cooling_device * -cpufreq_cooling_register(const struct cpumask *clip_cpus) +cpufreq_cooling_register(struct cpufreq_policy *policy) { return ERR_PTR(-ENOSYS); } static inline struct thermal_cooling_device * -cpufreq_power_cooling_register(const struct cpumask *clip_cpus, +cpufreq_power_cooling_register(struct cpufreq_policy *policy, u32 capacitance, get_static_t plat_static_func) { return NULL; @@ -98,14 +99,14 @@ cpufreq_power_cooling_register(const struct cpumask *clip_cpus, static inline struct thermal_cooling_device * of_cpufreq_cooling_register(struct device_node *np, - const struct cpumask *clip_cpus) + struct cpufreq_policy *policy) { return ERR_PTR(-ENOSYS); } static inline struct thermal_cooling_device * of_cpufreq_power_cooling_register(struct device_node *np, - const struct cpumask *clip_cpus, + struct cpufreq_policy *policy, u32 capacitance, get_static_t plat_static_func) { @@ -117,11 +118,6 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev) { return; } -static inline -unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq) -{ - return THERMAL_CSTATE_INVALID; -} #endif /* CONFIG_CPU_THERMAL */ #endif /* __CPU_COOLING_H__ */ diff --git a/include/linux/cpufreq.h b/include/linux/cpufreq.h index 905117bd5012..f10a9b3761cd 100644 --- a/include/linux/cpufreq.h +++ b/include/linux/cpufreq.h @@ -862,6 +862,20 @@ static inline int cpufreq_frequency_table_target(struct cpufreq_policy *policy, return -EINVAL; } } + +static inline int cpufreq_table_count_valid_entries(const struct cpufreq_policy *policy) +{ + struct cpufreq_frequency_table *pos; + int count = 0; + + if (unlikely(!policy->freq_table)) + return 0; + + cpufreq_for_each_valid_entry(pos, policy->freq_table) + count++; + + return count; +} #else static inline int cpufreq_boost_trigger_state(int state) { |