diff options
author | Anson Huang <anson.huang@nxp.com> | 2018-11-21 05:49:36 +0000 |
---|---|---|
committer | Eduardo Valentin <edubezval@gmail.com> | 2019-01-02 04:47:12 -0800 |
commit | c589c56671c914fbd6b56a6f92dce80edbbfdada (patch) | |
tree | 2f49329b823a3b0551214d2e43a7e978802a957a /drivers/thermal | |
parent | 4ab248b3b10a58e379e2d32333fff99ea5ca256c (diff) |
thermal: imx: fix for dependency on cpu-freq
The thermal driver is a standalone driver for monitoring SoC temperature
by enabling thermal sensor, so it can be enabled even when CONFIG_CPU_FREQ
is NOT set. So remove the dependency with CPU_THERMAL.
Introduce dummy function of legacy cooling register/unregister to make
thermal driver probe successfully when CONFIG_CPU_FREQ is NOT set.
Signed-off-by: Anson Huang <Anson.Huang@nxp.com>
Acked-by: Viresh Kumar <viresh.kumar@linaro.org>
Reviewed-by: Daniel Lezcano <daniel.lezcano@linaro.org>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
Diffstat (limited to 'drivers/thermal')
-rw-r--r-- | drivers/thermal/Kconfig | 2 | ||||
-rw-r--r-- | drivers/thermal/imx_thermal.c | 47 |
2 files changed, 36 insertions, 13 deletions
diff --git a/drivers/thermal/Kconfig b/drivers/thermal/Kconfig index 5422523c03f8..93bd3bbefb9a 100644 --- a/drivers/thermal/Kconfig +++ b/drivers/thermal/Kconfig @@ -212,7 +212,7 @@ config HISI_THERMAL config IMX_THERMAL tristate "Temperature sensor driver for Freescale i.MX SoCs" - depends on (ARCH_MXC && CPU_THERMAL) || COMPILE_TEST + depends on ARCH_MXC || COMPILE_TEST depends on NVMEM || !NVMEM depends on MFD_SYSCON depends on OF diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c index 15661549eb67..c924396685a0 100644 --- a/drivers/thermal/imx_thermal.c +++ b/drivers/thermal/imx_thermal.c @@ -648,15 +648,24 @@ static const struct of_device_id of_imx_thermal_match[] = { }; MODULE_DEVICE_TABLE(of, of_imx_thermal_match); +#ifdef CONFIG_CPU_FREQ /* * Create cooling device in case no #cooling-cells property is available in * CPU node */ static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data) { - struct device_node *np = of_get_cpu_node(data->policy->cpu, NULL); + struct device_node *np; int ret; + data->policy = cpufreq_cpu_get(0); + if (!data->policy) { + pr_debug("%s: CPUFreq policy not found\n", __func__); + return -EPROBE_DEFER; + } + + np = of_get_cpu_node(data->policy->cpu, NULL); + if (!np || !of_find_property(np, "#cooling-cells", NULL)) { data->cdev = cpufreq_cooling_register(data->policy); if (IS_ERR(data->cdev)) { @@ -669,6 +678,24 @@ static int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data) return 0; } +static void imx_thermal_unregister_legacy_cooling(struct imx_thermal_data *data) +{ + cpufreq_cooling_unregister(data->cdev); + cpufreq_cpu_put(data->policy); +} + +#else + +static inline int imx_thermal_register_legacy_cooling(struct imx_thermal_data *data) +{ + return 0; +} + +static inline void imx_thermal_unregister_legacy_cooling(struct imx_thermal_data *data) +{ +} +#endif + static int imx_thermal_probe(struct platform_device *pdev) { struct imx_thermal_data *data; @@ -743,14 +770,11 @@ static int imx_thermal_probe(struct platform_device *pdev) regmap_write(map, data->socdata->sensor_ctrl + REG_SET, data->socdata->power_down_mask); - data->policy = cpufreq_cpu_get(0); - if (!data->policy) { - pr_debug("%s: CPUFreq policy not found\n", __func__); - return -EPROBE_DEFER; - } - ret = imx_thermal_register_legacy_cooling(data); if (ret) { + if (ret == -EPROBE_DEFER) + return ret; + dev_err(&pdev->dev, "failed to register cpufreq cooling device: %d\n", ret); return ret; @@ -762,7 +786,7 @@ static int imx_thermal_probe(struct platform_device *pdev) if (ret != -EPROBE_DEFER) dev_err(&pdev->dev, "failed to get thermal clk: %d\n", ret); - goto cpufreq_put; + goto legacy_cleanup; } /* @@ -775,7 +799,7 @@ static int imx_thermal_probe(struct platform_device *pdev) ret = clk_prepare_enable(data->thermal_clk); if (ret) { dev_err(&pdev->dev, "failed to enable thermal clk: %d\n", ret); - goto cpufreq_put; + goto legacy_cleanup; } data->tz = thermal_zone_device_register("imx_thermal_zone", @@ -829,9 +853,8 @@ thermal_zone_unregister: thermal_zone_device_unregister(data->tz); clk_disable: clk_disable_unprepare(data->thermal_clk); -cpufreq_put: - cpufreq_cooling_unregister(data->cdev); - cpufreq_cpu_put(data->policy); +legacy_cleanup: + imx_thermal_unregister_legacy_cooling(data); return ret; } |