summaryrefslogtreecommitdiff
path: root/drivers/pwm/pwm-dwc-core.c
diff options
context:
space:
mode:
authorBen Dooks <ben.dooks@codethink.co.uk>2023-09-07 17:12:39 +0100
committerThierry Reding <thierry.reding@gmail.com>2023-10-13 10:07:17 +0200
commit4aff152d14c14f60dba7dad4ed0014d6e7c0cd0a (patch)
treedb6b1b5a670f123b6983b48ac3174039f1bcdbed /drivers/pwm/pwm-dwc-core.c
parent81432e2e5132e681874f500220c21dc3fdfda42b (diff)
pwm: dwc: add PWM bit unset in get_state call
If we are not in PWM mode, then the output is technically a 50% output based on a single timer instead of the high-low based on the two counters. Add a check for the PWM mode in dwc_pwm_get_state() and if DWC_TIM_CTRL_PWM is not set, then return a 50% cycle. This may only be an issue on initialisation, as the rest of the code currently assumes we're always going to have the extended PWM mode using two counters. Signed-off-by: Ben Dooks <ben.dooks@codethink.co.uk> Reviewed-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Link: https://lore.kernel.org/r/20230907161242.67190-4-ben.dooks@codethink.co.uk Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de> Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
Diffstat (limited to 'drivers/pwm/pwm-dwc-core.c')
-rw-r--r--drivers/pwm/pwm-dwc-core.c30
1 files changed, 19 insertions, 11 deletions
diff --git a/drivers/pwm/pwm-dwc-core.c b/drivers/pwm/pwm-dwc-core.c
index 8e716470390e..ea63dd741f5c 100644
--- a/drivers/pwm/pwm-dwc-core.c
+++ b/drivers/pwm/pwm-dwc-core.c
@@ -122,24 +122,32 @@ static int dwc_pwm_get_state(struct pwm_chip *chip, struct pwm_device *pwm,
{
struct dwc_pwm *dwc = to_dwc_pwm(chip);
u64 duty, period;
+ u32 ctrl, ld, ld2;
pm_runtime_get_sync(chip->dev);
- state->enabled = !!(dwc_pwm_readl(dwc,
- DWC_TIM_CTRL(pwm->hwpwm)) & DWC_TIM_CTRL_EN);
+ ctrl = dwc_pwm_readl(dwc, DWC_TIM_CTRL(pwm->hwpwm));
+ ld = dwc_pwm_readl(dwc, DWC_TIM_LD_CNT(pwm->hwpwm));
+ ld2 = dwc_pwm_readl(dwc, DWC_TIM_LD_CNT2(pwm->hwpwm));
- duty = dwc_pwm_readl(dwc, DWC_TIM_LD_CNT(pwm->hwpwm));
- duty += 1;
- duty *= dwc->clk_ns;
- state->duty_cycle = duty;
+ state->enabled = !!(ctrl & DWC_TIM_CTRL_EN);
- period = dwc_pwm_readl(dwc, DWC_TIM_LD_CNT2(pwm->hwpwm));
- period += 1;
- period *= dwc->clk_ns;
- period += duty;
- state->period = period;
+ /*
+ * If we're not in PWM, technically the output is a 50-50
+ * based on the timer load-count only.
+ */
+ if (ctrl & DWC_TIM_CTRL_PWM) {
+ duty = (ld + 1) * dwc->clk_ns;
+ period = (ld2 + 1) * dwc->clk_ns;
+ period += duty;
+ } else {
+ duty = (ld + 1) * dwc->clk_ns;
+ period = duty * 2;
+ }
state->polarity = PWM_POLARITY_INVERSED;
+ state->period = period;
+ state->duty_cycle = duty;
pm_runtime_put_sync(chip->dev);