diff options
author | Viresh Kumar <viresh.kumar@linaro.org> | 2021-08-11 10:22:55 +0530 |
---|---|---|
committer | Viresh Kumar <viresh.kumar@linaro.org> | 2021-08-12 09:54:07 +0530 |
commit | bb8c26d9387fe428068dcab35b1873ea3b881de1 (patch) | |
tree | 92d9de370cbfa5864d443dc7d52ed76f41a647e8 | |
parent | 484f2b7c61b9ae58cc00c5127bcbcd9177af8dfe (diff) |
cpufreq: vexpress: Set CPUFREQ_IS_COOLING_DEV flag
Reuse the cpufreq core's registration of cooling device by setting the
CPUFREQ_IS_COOLING_DEV flag. Set this only if bL switcher isn't enabled.
Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
-rw-r--r-- | drivers/cpufreq/vexpress-spc-cpufreq.c | 22 |
1 files changed, 3 insertions, 19 deletions
diff --git a/drivers/cpufreq/vexpress-spc-cpufreq.c b/drivers/cpufreq/vexpress-spc-cpufreq.c index 51dfa9ae6cf5..ab56813b7256 100644 --- a/drivers/cpufreq/vexpress-spc-cpufreq.c +++ b/drivers/cpufreq/vexpress-spc-cpufreq.c @@ -15,7 +15,6 @@ #include <linux/cpu.h> #include <linux/cpufreq.h> #include <linux/cpumask.h> -#include <linux/cpu_cooling.h> #include <linux/device.h> #include <linux/module.h> #include <linux/mutex.h> @@ -47,7 +46,6 @@ static bool bL_switching_enabled; #define ACTUAL_FREQ(cluster, freq) ((cluster == A7_CLUSTER) ? freq << 1 : freq) #define VIRT_FREQ(cluster, freq) ((cluster == A7_CLUSTER) ? freq >> 1 : freq) -static struct thermal_cooling_device *cdev[MAX_CLUSTERS]; static struct clk *clk[MAX_CLUSTERS]; static struct cpufreq_frequency_table *freq_table[MAX_CLUSTERS + 1]; static atomic_t cluster_usage[MAX_CLUSTERS + 1]; @@ -457,11 +455,6 @@ static int ve_spc_cpufreq_exit(struct cpufreq_policy *policy) struct device *cpu_dev; int cur_cluster = cpu_to_cluster(policy->cpu); - if (cur_cluster < MAX_CLUSTERS) { - cpufreq_cooling_unregister(cdev[cur_cluster]); - cdev[cur_cluster] = NULL; - } - cpu_dev = get_cpu_device(policy->cpu); if (!cpu_dev) { pr_err("%s: failed to get cpu%d device\n", __func__, @@ -473,17 +466,6 @@ static int ve_spc_cpufreq_exit(struct cpufreq_policy *policy) return 0; } -static void ve_spc_cpufreq_ready(struct cpufreq_policy *policy) -{ - int cur_cluster = cpu_to_cluster(policy->cpu); - - /* Do not register a cpu_cooling device if we are in IKS mode */ - if (cur_cluster >= MAX_CLUSTERS) - return; - - cdev[cur_cluster] = of_cpufreq_cooling_register(policy); -} - static struct cpufreq_driver ve_spc_cpufreq_driver = { .name = "vexpress-spc", .flags = CPUFREQ_HAVE_GOVERNOR_PER_POLICY | @@ -493,7 +475,6 @@ static struct cpufreq_driver ve_spc_cpufreq_driver = { .get = ve_spc_cpufreq_get_rate, .init = ve_spc_cpufreq_init, .exit = ve_spc_cpufreq_exit, - .ready = ve_spc_cpufreq_ready, .attr = cpufreq_generic_attr, }; @@ -553,6 +534,9 @@ static int ve_spc_cpufreq_probe(struct platform_device *pdev) for (i = 0; i < MAX_CLUSTERS; i++) mutex_init(&cluster_lock[i]); + if (!is_bL_switching_enabled()) + ve_spc_cpufreq_driver.flags |= CPUFREQ_IS_COOLING_DEV; + ret = cpufreq_register_driver(&ve_spc_cpufreq_driver); if (ret) { pr_info("%s: Failed registering platform driver: %s, err: %d\n", |