summaryrefslogtreecommitdiff
path: root/Documentation/power
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2012-05-31 12:10:15 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2012-05-31 12:10:15 -0700
commit76f901eb4659779ecacd0e4eba49f55442daef53 (patch)
tree0761f03211ffdfc06216eabeb61b02ef6d598d3c /Documentation/power
parentbd0e162d0312aa95e8b85ba883efddebf27be121 (diff)
parent96facd23e45e6d5020be135c8ab392ba9e044fa4 (diff)
Merge tag 'for-v3.5' of git://git.infradead.org/battery-2.6
Pull battery updates from Anton Vorontsov: "A bunch of fixes for v3.5, nothing extraordinary." * tag 'for-v3.5' of git://git.infradead.org/battery-2.6: (27 commits) smb347-charger: Include missing <linux/err.h> smb347-charger: Clean up battery attributes max17042_battery: Add support for max17047/50 chip sbs-battery.c: Capacity attr = remaining relative capacity isp1704_charger: Use after free on probe error ds2781_battery: Use DS2781_PARAM_EEPROM_SIZE and DS2781_USER_EEPROM_SIZE power_supply: Fix a typo in BATTERY_DS2781 Kconfig entry charger-manager: Provide cm_notify_event function for in-kernel use charger-manager: Poll battery health in normal state smb347-charger: Convert to regmap API smb347-charger: Move IRQ enabling to the end of probe smb347-charger: Rename few functions to match better what they are doing smb347-charger: Convert to use module_i2c_driver() smb347_charger: Cleanup power supply registration code in probe ab8500: Clean up probe routines ab8500_fg: Harden platform data check ab8500_btemp: Harden platform data check ab8500_charger: Harden platform data check MAINTAINERS: Fix 'F' entry for the power supply class max17042_battery: Handle irq request failure case ...
Diffstat (limited to 'Documentation/power')
-rw-r--r--Documentation/power/charger-manager.txt41
-rw-r--r--Documentation/power/power_supply_class.txt2
2 files changed, 41 insertions, 2 deletions
diff --git a/Documentation/power/charger-manager.txt b/Documentation/power/charger-manager.txt
index fdcca991df3..b4f7f4b23f6 100644
--- a/Documentation/power/charger-manager.txt
+++ b/Documentation/power/charger-manager.txt
@@ -44,6 +44,16 @@ Charger Manager supports the following:
Normally, the platform will need to resume and suspend some devices
that are used by Charger Manager.
+* Support for premature full-battery event handling
+ If the battery voltage drops by "fullbatt_vchkdrop_uV" after
+ "fullbatt_vchkdrop_ms" from the full-battery event, the framework
+ restarts charging. This check is also performed while suspended by
+ setting wakeup time accordingly and using suspend_again.
+
+* Support for uevent-notify
+ With the charger-related events, the device sends
+ notification to users with UEVENT.
+
2. Global Charger-Manager Data related with suspend_again
========================================================
In order to setup Charger Manager with suspend-again feature
@@ -55,7 +65,7 @@ if there are multiple batteries. If there are multiple batteries, the
multiple instances of Charger Manager share the same charger_global_desc
and it will manage in-suspend monitoring for all instances of Charger Manager.
-The user needs to provide all the two entries properly in order to activate
+The user needs to provide all the three entries properly in order to activate
in-suspend monitoring:
struct charger_global_desc {
@@ -74,6 +84,11 @@ bool (*rtc_only_wakeup)(void);
same struct. If there is any other wakeup source triggered the
wakeup, it should return false. If the "rtc" is the only wakeup
reason, it should return true.
+
+bool assume_timer_stops_in_suspend;
+ : if true, Charger Manager assumes that
+ the timer (CM uses jiffies as timer) stops during suspend. Then, CM
+ assumes that the suspend-duration is same as the alarm length.
};
3. How to setup suspend_again
@@ -111,6 +126,16 @@ enum polling_modes polling_mode;
CM_POLL_CHARGING_ONLY: poll this battery if and only if the
battery is being charged.
+unsigned int fullbatt_vchkdrop_ms;
+unsigned int fullbatt_vchkdrop_uV;
+ : If both have non-zero values, Charger Manager will check the
+ battery voltage drop fullbatt_vchkdrop_ms after the battery is fully
+ charged. If the voltage drop is over fullbatt_vchkdrop_uV, Charger
+ Manager will try to recharge the battery by disabling and enabling
+ chargers. Recharge with voltage drop condition only (without delay
+ condition) is needed to be implemented with hardware interrupts from
+ fuel gauges or charger devices/chips.
+
unsigned int fullbatt_uV;
: If specified with a non-zero value, Charger Manager assumes
that the battery is full (capacity = 100) if the battery is not being
@@ -122,6 +147,8 @@ unsigned int polling_interval_ms;
this battery every polling_interval_ms or more frequently.
enum data_source battery_present;
+ : CM_BATTERY_PRESENT: assume that the battery exists.
+ CM_NO_BATTERY: assume that the battery does not exists.
CM_FUEL_GAUGE: get battery presence information from fuel gauge.
CM_CHARGER_STAT: get battery presence from chargers.
@@ -151,7 +178,17 @@ bool measure_battery_temp;
the value of measure_battery_temp.
};
-5. Other Considerations
+5. Notify Charger-Manager of charger events: cm_notify_event()
+=========================================================
+If there is an charger event is required to notify
+Charger Manager, a charger device driver that triggers the event can call
+cm_notify_event(psy, type, msg) to notify the corresponding Charger Manager.
+In the function, psy is the charger driver's power_supply pointer, which is
+associated with Charger-Manager. The parameter "type"
+is the same as irq's type (enum cm_event_types). The event message "msg" is
+optional and is effective only if the event type is "UNDESCRIBED" or "OTHERS".
+
+6. Other Considerations
=======================
At the charger/battery-related events such as battery-pulled-out,
diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt
index 9f16c5178b6..211831d4095 100644
--- a/Documentation/power/power_supply_class.txt
+++ b/Documentation/power/power_supply_class.txt
@@ -84,6 +84,8 @@ are already charged or discharging, 'n/a' can be displayed (or
HEALTH - represents health of the battery, values corresponds to
POWER_SUPPLY_HEALTH_*, defined in battery.h.
+VOLTAGE_OCV - open circuit voltage of the battery.
+
VOLTAGE_MAX_DESIGN, VOLTAGE_MIN_DESIGN - design values for maximal and
minimal power supply voltages. Maximal/minimal means values of voltages
when battery considered "full"/"empty" at normal conditions. Yes, there is