diff --git a/drivers/power/charger-manager.c b/drivers/power/charger-manager.c
new file mode 100644
index 000000000000..0378d019efae
--- /dev/null
+++ b/drivers/power/charger-manager.c
@@ -0,0 +1,1072 @@
+/*
+ * Copyright (C) 2011 Samsung Electronics Co., Ltd.
+ * MyungJoo Ham <myungjoo.ham@samsung.com>
+ *
+ * This driver enables to monitor battery health and control charger
+ * during suspend-to-mem.
+ * Charger manager depends on other devices. register this later than
+ * the depending devices.
+ *
+ * This program is free software; you can redistribute it and/or modify
+ * it under the terms of the GNU General Public License version 2 as
+ * published by the Free Software Foundation.
+**/
+
+#include <linux/io.h>
+#include <linux/module.h>
+#include <linux/irq.h>
+#include <linux/interrupt.h>
+#include <linux/rtc.h>
+#include <linux/slab.h>
+#include <linux/workqueue.h>
+#include <linux/platform_device.h>
+#include <linux/power/charger-manager.h>
+#include <linux/regulator/consumer.h>
+
+/*
+ * Regard CM_JIFFIES_SMALL jiffies is small enough to ignore for
+ * delayed works so that we can run delayed works with CM_JIFFIES_SMALL
+ * without any delays.
+ */
+#define CM_JIFFIES_SMALL (2)
+
+/* If y is valid (> 0) and smaller than x, do x = y */
+#define CM_MIN_VALID(x, y) x = (((y > 0) && ((x) > (y))) ? (y) : (x))
+
+/*
+ * Regard CM_RTC_SMALL (sec) is small enough to ignore error in invoking
+ * rtc alarm. It should be 2 or larger
+ */
+#define CM_RTC_SMALL (2)
+
+#define UEVENT_BUF_SIZE 32
+
+static LIST_HEAD(cm_list);
+static DEFINE_MUTEX(cm_list_mtx);
+
+/* About in-suspend (suspend-again) monitoring */
+static struct rtc_device *rtc_dev;
+/*
+ * Backup RTC alarm
+ * Save the wakeup alarm before entering suspend-to-RAM
+ */
+static struct rtc_wkalrm rtc_wkalarm_save;
+/* Backup RTC alarm time in terms of seconds since 01-01-1970 00:00:00 */
+static unsigned long rtc_wkalarm_save_time;
+static bool cm_suspended;
+static bool cm_rtc_set;
+static unsigned long cm_suspend_duration_ms;
+
+/* Global charger-manager description */
+static struct charger_global_desc *g_desc; /* init with setup_charger_manager */
+
+/**
+ * is_batt_present - See if the battery presents in place.
+ * @cm: the Charger Manager representing the battery.
+ */
+static bool is_batt_present(struct charger_manager *cm)
+{
+ union power_supply_propval val;
+ bool present = false;
+ int i, ret;
+
+ switch (cm->desc->battery_present) {
+ case CM_FUEL_GAUGE:
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_PRESENT, &val);
+ if (ret == 0 && val.intval)
+ present = true;
+ break;
+ case CM_CHARGER_STAT:
+ for (i = 0; cm->charger_stat[i]; i++) {
+ ret = cm->charger_stat[i]->get_property(
+ cm->charger_stat[i],
+ POWER_SUPPLY_PROP_PRESENT, &val);
+ if (ret == 0 && val.intval) {
+ present = true;
+ break;
+ }
+ }
+ break;
+ }
+
+ return present;
+}
+
+/**
+ * is_ext_pwr_online - See if an external power source is attached to charge
+ * @cm: the Charger Manager representing the battery.
+ *
+ * Returns true if at least one of the chargers of the battery has an external
+ * power source attached to charge the battery regardless of whether it is
+ * actually charging or not.
+ */
+static bool is_ext_pwr_online(struct charger_manager *cm)
+{
+ union power_supply_propval val;
+ bool online = false;
+ int i, ret;
+
+ /* If at least one of them has one, it's yes. */
+ for (i = 0; cm->charger_stat[i]; i++) {
+ ret = cm->charger_stat[i]->get_property(
+ cm->charger_stat[i],
+ POWER_SUPPLY_PROP_ONLINE, &val);
+ if (ret == 0 && val.intval) {
+ online = true;
+ break;
+ }
+ }
+
+ return online;
+}
+
+/**
+ * get_batt_uV - Get the voltage level of the battery
+ * @cm: the Charger Manager representing the battery.
+ * @uV: the voltage level returned.
+ *
+ * Returns 0 if there is no error.
+ * Returns a negative value on error.
+ */
+static int get_batt_uV(struct charger_manager *cm, int *uV)
+{
+ union power_supply_propval val;
+ int ret;
+
+ if (cm->fuel_gauge)
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_VOLTAGE_NOW, &val);
+ else
+ return -ENODEV;
+
+ if (ret)
+ return ret;
+
+ *uV = val.intval;
+ return 0;
+}
+
+/**
+ * is_charging - Returns true if the battery is being charged.
+ * @cm: the Charger Manager representing the battery.
+ */
+static bool is_charging(struct charger_manager *cm)
+{
+ int i, ret;
+ bool charging = false;
+ union power_supply_propval val;
+
+ /* If there is no battery, it cannot be charged */
+ if (!is_batt_present(cm))
+ return false;
+
+ /* If at least one of the charger is charging, return yes */
+ for (i = 0; cm->charger_stat[i]; i++) {
+ /* 1. The charger sholuld not be DISABLED */
+ if (cm->emergency_stop)
+ continue;
+ if (!cm->charger_enabled)
+ continue;
+
+ /* 2. The charger should be online (ext-power) */
+ ret = cm->charger_stat[i]->get_property(
+ cm->charger_stat[i],
+ POWER_SUPPLY_PROP_ONLINE, &val);
+ if (ret) {
+ dev_warn(cm->dev, "Cannot read ONLINE value from %s.\n",
+ cm->desc->psy_charger_stat[i]);
+ continue;
+ }
+ if (val.intval == 0)
+ continue;
+
+ /*
+ * 3. The charger should not be FULL, DISCHARGING,
+ * or NOT_CHARGING.
+ */
+ ret = cm->charger_stat[i]->get_property(
+ cm->charger_stat[i],
+ POWER_SUPPLY_PROP_STATUS, &val);
+ if (ret) {
+ dev_warn(cm->dev, "Cannot read STATUS value from %s.\n",
+ cm->desc->psy_charger_stat[i]);
+ continue;
+ }
+ if (val.intval == POWER_SUPPLY_STATUS_FULL ||
+ val.intval == POWER_SUPPLY_STATUS_DISCHARGING ||
+ val.intval == POWER_SUPPLY_STATUS_NOT_CHARGING)
+ continue;
+
+ /* Then, this is charging. */
+ charging = true;
+ break;
+ }
+
+ return charging;
+}
+
+/**
+ * is_polling_required - Return true if need to continue polling for this CM.
+ * @cm: the Charger Manager representing the battery.
+ */
+static bool is_polling_required(struct charger_manager *cm)
+{
+ switch (cm->desc->polling_mode) {
+ case CM_POLL_DISABLE:
+ return false;
+ case CM_POLL_ALWAYS:
+ return true;
+ case CM_POLL_EXTERNAL_POWER_ONLY:
+ return is_ext_pwr_online(cm);
+ case CM_POLL_CHARGING_ONLY:
+ return is_charging(cm);
+ default:
+ dev_warn(cm->dev, "Incorrect polling_mode (%d)\n",
+ cm->desc->polling_mode);
+ }
+
+ return false;
+}
+
+/**
+ * try_charger_enable - Enable/Disable chargers altogether
+ * @cm: the Charger Manager representing the battery.
+ * @enable: true: enable / false: disable
+ *
+ * Note that Charger Manager keeps the charger enabled regardless whether
+ * the charger is charging or not (because battery is full or no external
+ * power source exists) except when CM needs to disable chargers forcibly
+ * bacause of emergency causes; when the battery is overheated or too cold.
+ */
+static int try_charger_enable(struct charger_manager *cm, bool enable)
+{
+ int err = 0, i;
+ struct charger_desc *desc = cm->desc;
+
+ /* Ignore if it's redundent command */
+ if (enable && cm->charger_enabled)
+ return 0;
+ if (!enable && !cm->charger_enabled)
+ return 0;
+
+ if (enable) {
+ if (cm->emergency_stop)
+ return -EAGAIN;
+ err = regulator_bulk_enable(desc->num_charger_regulators,
+ desc->charger_regulators);
+ } else {
+ /*
+ * Abnormal battery state - Stop charging forcibly,
+ * even if charger was enabled at the other places
+ */
+ err = regulator_bulk_disable(desc->num_charger_regulators,
+ desc->charger_regulators);
+
+ for (i = 0; i < desc->num_charger_regulators; i++) {
+ if (regulator_is_enabled(
+ desc->charger_regulators[i].consumer)) {
+ regulator_force_disable(
+ desc->charger_regulators[i].consumer);
+ dev_warn(cm->dev,
+ "Disable regulator(%s) forcibly.\n",
+ desc->charger_regulators[i].supply);
+ }
+ }
+ }
+
+ if (!err)
+ cm->charger_enabled = enable;
+
+ return err;
+}
+
+/**
+ * uevent_notify - Let users know something has changed.
+ * @cm: the Charger Manager representing the battery.
+ * @event: the event string.
+ *
+ * If @event is null, it implies that uevent_notify is called
+ * by resume function. When called in the resume function, cm_suspended
+ * should be already reset to false in order to let uevent_notify
+ * notify the recent event during the suspend to users. While
+ * suspended, uevent_notify does not notify users, but tracks
+ * events so that uevent_notify can notify users later after resumed.
+ */
+static void uevent_notify(struct charger_manager *cm, const char *event)
+{
+ static char env_str[UEVENT_BUF_SIZE + 1] = "";
+ static char env_str_save[UEVENT_BUF_SIZE + 1] = "";
+
+ if (cm_suspended) {
+ /* Nothing in suspended-event buffer */
+ if (env_str_save[0] == 0) {
+ if (!strncmp(env_str, event, UEVENT_BUF_SIZE))
+ return; /* status not changed */
+ strncpy(env_str_save, event, UEVENT_BUF_SIZE);
+ return;
+ }
+
+ if (!strncmp(env_str_save, event, UEVENT_BUF_SIZE))
+ return; /* Duplicated. */
+ else
+ strncpy(env_str_save, event, UEVENT_BUF_SIZE);
+
+ return;
+ }
+
+ if (event == NULL) {
+ /* No messages pending */
+ if (!env_str_save[0])
+ return;
+
+ strncpy(env_str, env_str_save, UEVENT_BUF_SIZE);
+ kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE);
+ env_str_save[0] = 0;
+
+ return;
+ }
+
+ /* status not changed */
+ if (!strncmp(env_str, event, UEVENT_BUF_SIZE))
+ return;
+
+ /* save the status and notify the update */
+ strncpy(env_str, event, UEVENT_BUF_SIZE);
+ kobject_uevent(&cm->dev->kobj, KOBJ_CHANGE);
+
+ dev_info(cm->dev, event);
+}
+
+/**
+ * _cm_monitor - Monitor the temperature and return true for exceptions.
+ * @cm: the Charger Manager representing the battery.
+ *
+ * Returns true if there is an event to notify for the battery.
+ * (True if the status of "emergency_stop" changes)
+ */
+static bool _cm_monitor(struct charger_manager *cm)
+{
+ struct charger_desc *desc = cm->desc;
+ int temp = desc->temperature_out_of_range(&cm->last_temp_mC);
+
+ dev_dbg(cm->dev, "monitoring (%2.2d.%3.3dC)\n",
+ cm->last_temp_mC / 1000, cm->last_temp_mC % 1000);
+
+ /* It has been stopped or charging already */
+ if (!!temp == !!cm->emergency_stop)
+ return false;
+
+ if (temp) {
+ cm->emergency_stop = temp;
+ if (!try_charger_enable(cm, false)) {
+ if (temp > 0)
+ uevent_notify(cm, "OVERHEAT");
+ else
+ uevent_notify(cm, "COLD");
+ }
+ } else {
+ cm->emergency_stop = 0;
+ if (!try_charger_enable(cm, true))
+ uevent_notify(cm, "CHARGING");
+ }
+
+ return true;
+}
+
+/**
+ * cm_monitor - Monitor every battery.
+ *
+ * Returns true if there is an event to notify from any of the batteries.
+ * (True if the status of "emergency_stop" changes)
+ */
+static bool cm_monitor(void)
+{
+ bool stop = false;
+ struct charger_manager *cm;
+
+ mutex_lock(&cm_list_mtx);
+
+ list_for_each_entry(cm, &cm_list, entry)
+ stop = stop || _cm_monitor(cm);
+
+ mutex_unlock(&cm_list_mtx);
+
+ return stop;
+}
+
+static int charger_get_property(struct power_supply *psy,
+ enum power_supply_property psp,
+ union power_supply_propval *val)
+{
+ struct charger_manager *cm = container_of(psy,
+ struct charger_manager, charger_psy);
+ struct charger_desc *desc = cm->desc;
+ int i, ret = 0, uV;
+
+ switch (psp) {
+ case POWER_SUPPLY_PROP_STATUS:
+ if (is_charging(cm))
+ val->intval = POWER_SUPPLY_STATUS_CHARGING;
+ else if (is_ext_pwr_online(cm))
+ val->intval = POWER_SUPPLY_STATUS_NOT_CHARGING;
+ else
+ val->intval = POWER_SUPPLY_STATUS_DISCHARGING;
+ break;
+ case POWER_SUPPLY_PROP_HEALTH:
+ if (cm->emergency_stop > 0)
+ val->intval = POWER_SUPPLY_HEALTH_OVERHEAT;
+ else if (cm->emergency_stop < 0)
+ val->intval = POWER_SUPPLY_HEALTH_COLD;
+ else
+ val->intval = POWER_SUPPLY_HEALTH_GOOD;
+ break;
+ case POWER_SUPPLY_PROP_PRESENT:
+ if (is_batt_present(cm))
+ val->intval = 1;
+ else
+ val->intval = 0;
+ break;
+ case POWER_SUPPLY_PROP_VOLTAGE_NOW:
+ ret = get_batt_uV(cm, &i);
+ val->intval = i;
+ break;
+ case POWER_SUPPLY_PROP_CURRENT_NOW:
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CURRENT_NOW, val);
+ break;
+ case POWER_SUPPLY_PROP_TEMP:
+ /* in thenth of centigrade */
+ if (cm->last_temp_mC == INT_MIN)
+ desc->temperature_out_of_range(&cm->last_temp_mC);
+ val->intval = cm->last_temp_mC / 100;
+ if (!desc->measure_battery_temp)
+ ret = -ENODEV;
+ break;
+ case POWER_SUPPLY_PROP_TEMP_AMBIENT:
+ /* in thenth of centigrade */
+ if (cm->last_temp_mC == INT_MIN)
+ desc->temperature_out_of_range(&cm->last_temp_mC);
+ val->intval = cm->last_temp_mC / 100;
+ if (desc->measure_battery_temp)
+ ret = -ENODEV;
+ break;
+ case POWER_SUPPLY_PROP_CAPACITY:
+ if (!cm->fuel_gauge) {
+ ret = -ENODEV;
+ break;
+ }
+
+ if (!is_batt_present(cm)) {
+ /* There is no battery. Assume 100% */
+ val->intval = 100;
+ break;
+ }
+
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CAPACITY, val);
+ if (ret)
+ break;
+
+ if (val->intval > 100) {
+ val->intval = 100;
+ break;
+ }
+ if (val->intval < 0)
+ val->intval = 0;
+
+ /* Do not adjust SOC when charging: voltage is overrated */
+ if (is_charging(cm))
+ break;
+
+ /*
+ * If the capacity value is inconsistent, calibrate it base on
+ * the battery voltage values and the thresholds given as desc
+ */
+ ret = get_batt_uV(cm, &uV);
+ if (ret) {
+ /* Voltage information not available. No calibration */
+ ret = 0;
+ break;
+ }
+
+ if (desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
+ !is_charging(cm)) {
+ val->intval = 100;
+ break;
+ }
+
+ break;
+ case POWER_SUPPLY_PROP_ONLINE:
+ if (is_ext_pwr_online(cm))
+ val->intval = 1;
+ else
+ val->intval = 0;
+ break;
+ case POWER_SUPPLY_PROP_CHARGE_FULL:
+ if (cm->fuel_gauge) {
+ if (cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CHARGE_FULL, val) == 0)
+ break;
+ }
+
+ if (is_ext_pwr_online(cm)) {
+ /* Not full if it's charging. */
+ if (is_charging(cm)) {
+ val->intval = 0;
+ break;
+ }
+ /*
+ * Full if it's powered but not charging andi
+ * not forced stop by emergency
+ */
+ if (!cm->emergency_stop) {
+ val->intval = 1;
+ break;
+ }
+ }
+
+ /* Full if it's over the fullbatt voltage */
+ ret = get_batt_uV(cm, &uV);
+ if (!ret && desc->fullbatt_uV > 0 && uV >= desc->fullbatt_uV &&
+ !is_charging(cm)) {
+ val->intval = 1;
+ break;
+ }
+
+ /* Full if the cap is 100 */
+ if (cm->fuel_gauge) {
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CAPACITY, val);
+ if (!ret && val->intval >= 100 && !is_charging(cm)) {
+ val->intval = 1;
+ break;
+ }
+ }
+
+ val->intval = 0;
+ ret = 0;
+ break;
+ case POWER_SUPPLY_PROP_CHARGE_NOW:
+ if (is_charging(cm)) {
+ ret = cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CHARGE_NOW,
+ val);
+ if (ret) {
+ val->intval = 1;
+ ret = 0;
+ } else {
+ /* If CHARGE_NOW is supplied, use it */
+ val->intval = (val->intval > 0) ?
+ val->intval : 1;
+ }
+ } else {
+ val->intval = 0;
+ }
+ break;
+ default:
+ return -EINVAL;
+ }
+ return ret;
+}
+
+#define NUM_CHARGER_PSY_OPTIONAL (4)
+static enum power_supply_property default_charger_props[] = {
+ /* Guaranteed to provide */
+ POWER_SUPPLY_PROP_STATUS,
+ POWER_SUPPLY_PROP_HEALTH,
+ POWER_SUPPLY_PROP_PRESENT,
+ POWER_SUPPLY_PROP_VOLTAGE_NOW,
+ POWER_SUPPLY_PROP_CAPACITY,
+ POWER_SUPPLY_PROP_ONLINE,
+ POWER_SUPPLY_PROP_CHARGE_FULL,
+ /*
+ * Optional properties are:
+ * POWER_SUPPLY_PROP_CHARGE_NOW,
+ * POWER_SUPPLY_PROP_CURRENT_NOW,
+ * POWER_SUPPLY_PROP_TEMP, and
+ * POWER_SUPPLY_PROP_TEMP_AMBIENT,
+ */
+};
+
+static struct power_supply psy_default = {
+ .name = "battery",
+ .type = POWER_SUPPLY_TYPE_BATTERY,
+ .properties = default_charger_props,
+ .num_properties = ARRAY_SIZE(default_charger_props),
+ .get_property = charger_get_property,
+};
+
+/**
+ * cm_setup_timer - For in-suspend monitoring setup wakeup alarm
+ * for suspend_again.
+ *
+ * Returns true if the alarm is set for Charger Manager to use.
+ * Returns false if
+ * cm_setup_timer fails to set an alarm,
+ * cm_setup_timer does not need to set an alarm for Charger Manager,
+ * or an alarm previously configured is to be used.
+ */
+static bool cm_setup_timer(void)
+{
+ struct charger_manager *cm;
+ unsigned int wakeup_ms = UINT_MAX;
+ bool ret = false;
+
+ mutex_lock(&cm_list_mtx);
+
+ list_for_each_entry(cm, &cm_list, entry) {
+ /* Skip if polling is not required for this CM */
+ if (!is_polling_required(cm) && !cm->emergency_stop)
+ continue;
+ if (cm->desc->polling_interval_ms == 0)
+ continue;
+ CM_MIN_VALID(wakeup_ms, cm->desc->polling_interval_ms);
+ }
+
+ mutex_unlock(&cm_list_mtx);
+
+ if (wakeup_ms < UINT_MAX && wakeup_ms > 0) {
+ pr_info("Charger Manager wakeup timer: %u ms.\n", wakeup_ms);
+ if (rtc_dev) {
+ struct rtc_wkalrm tmp;
+ unsigned long time, now;
+ unsigned long add = DIV_ROUND_UP(wakeup_ms, 1000);
+
+ /*
+ * Set alarm with the polling interval (wakeup_ms)
+ * except when rtc_wkalarm_save comes first.
+ * However, the alarm time should be NOW +
+ * CM_RTC_SMALL or later.
+ */
+ tmp.enabled = 1;
+ rtc_read_time(rtc_dev, &tmp.time);
+ rtc_tm_to_time(&tmp.time, &now);
+ if (add < CM_RTC_SMALL)
+ add = CM_RTC_SMALL;
+ time = now + add;
+
+ ret = true;
+
+ if (rtc_wkalarm_save.enabled &&
+ rtc_wkalarm_save_time &&
+ rtc_wkalarm_save_time < time) {
+ if (rtc_wkalarm_save_time < now + CM_RTC_SMALL)
+ time = now + CM_RTC_SMALL;
+ else
+ time = rtc_wkalarm_save_time;
+
+ /* The timer is not appointed by CM */
+ ret = false;
+ }
+
+ pr_info("Waking up after %lu secs.\n",
+ time - now);
+
+ rtc_time_to_tm(time, &tmp.time);
+ rtc_set_alarm(rtc_dev, &tmp);
+ cm_suspend_duration_ms += wakeup_ms;
+ return ret;
+ }
+ }
+
+ if (rtc_dev)
+ rtc_set_alarm(rtc_dev, &rtc_wkalarm_save);
+ return false;
+}
+
+/**
+ * cm_suspend_again - Determine whether suspend again or not
+ *
+ * Returns true if the system should be suspended again
+ * Returns false if the system should be woken up
+ */
+bool cm_suspend_again(void)
+{
+ struct charger_manager *cm;
+ bool ret = false;
+
+ if (!g_desc || !g_desc->rtc_only_wakeup || !g_desc->rtc_only_wakeup() ||
+ !cm_rtc_set)
+ return false;
+
+ if (cm_monitor())
+ goto out;
+
+ ret = true;
+ mutex_lock(&cm_list_mtx);
+ list_for_each_entry(cm, &cm_list, entry) {
+ if (cm->status_save_ext_pwr_inserted != is_ext_pwr_online(cm) ||
+ cm->status_save_batt != is_batt_present(cm))
+ ret = false;
+ }
+ mutex_unlock(&cm_list_mtx);
+
+ cm_rtc_set = cm_setup_timer();
+out:
+ /* It's about the time when the non-CM appointed timer goes off */
+ if (rtc_wkalarm_save.enabled) {
+ unsigned long now;
+ struct rtc_time tmp;
+
+ rtc_read_time(rtc_dev, &tmp);
+ rtc_tm_to_time(&tmp, &now);
+
+ if (rtc_wkalarm_save_time &&
+ now + CM_RTC_SMALL >= rtc_wkalarm_save_time)
+ return false;
+ }
+ return ret;
+}
+EXPORT_SYMBOL_GPL(cm_suspend_again);
+
+/**
+ * setup_charger_manager - initialize charger_global_desc data
+ * @gd: pointer to instance of charger_global_desc
+ */
+int setup_charger_manager(struct charger_global_desc *gd)
+{
+ if (!gd)
+ return -EINVAL;
+
+ if (rtc_dev)
+ rtc_class_close(rtc_dev);
+ rtc_dev = NULL;
+ g_desc = NULL;
+
+ if (!gd->rtc_only_wakeup) {
+ pr_err("The callback rtc_only_wakeup is not given.\n");
+ return -EINVAL;
+ }
+
+ if (gd->rtc_name) {
+ rtc_dev = rtc_class_open(gd->rtc_name);
+ if (IS_ERR_OR_NULL(rtc_dev)) {
+ rtc_dev = NULL;
+ /* Retry at probe. RTC may be not registered yet */
+ }
+ } else {
+ pr_warn("No wakeup timer is given for charger manager."
+ "In-suspend monitoring won't work.\n");
+ }
+
+ g_desc = gd;
+ return 0;
+}
+EXPORT_SYMBOL_GPL(setup_charger_manager);
+
+static int charger_manager_probe(struct platform_device *pdev)
+{
+ struct charger_desc *desc = dev_get_platdata(&pdev->dev);
+ struct charger_manager *cm;
+ int ret = 0, i = 0;
+ union power_supply_propval val;
+
+ if (g_desc && !rtc_dev && g_desc->rtc_name) {
+ rtc_dev = rtc_class_open(g_desc->rtc_name);
+ if (IS_ERR_OR_NULL(rtc_dev)) {
+ rtc_dev = NULL;
+ dev_err(&pdev->dev, "Cannot get RTC %s.\n",
+ g_desc->rtc_name);
+ ret = -ENODEV;
+ goto err_alloc;
+ }
+ }
+
+ if (!desc) {
+ dev_err(&pdev->dev, "No platform data (desc) found.\n");
+ ret = -ENODEV;
+ goto err_alloc;
+ }
+
+ cm = kzalloc(sizeof(struct charger_manager), GFP_KERNEL);
+ if (!cm) {
+ dev_err(&pdev->dev, "Cannot allocate memory.\n");
+ ret = -ENOMEM;
+ goto err_alloc;
+ }
+
+ /* Basic Values. Unspecified are Null or 0 */
+ cm->dev = &pdev->dev;
+ cm->desc = kzalloc(sizeof(struct charger_desc), GFP_KERNEL);
+ if (!cm->desc) {
+ dev_err(&pdev->dev, "Cannot allocate memory.\n");
+ ret = -ENOMEM;
+ goto err_alloc_desc;
+ }
+ memcpy(cm->desc, desc, sizeof(struct charger_desc));
+ cm->last_temp_mC = INT_MIN; /* denotes "unmeasured, yet" */
+
+ if (!desc->charger_regulators || desc->num_charger_regulators < 1) {
+ ret = -EINVAL;
+ dev_err(&pdev->dev, "charger_regulators undefined.\n");
+ goto err_no_charger;
+ }
+
+ if (!desc->psy_charger_stat || !desc->psy_charger_stat[0]) {
+ dev_err(&pdev->dev, "No power supply defined.\n");
+ ret = -EINVAL;
+ goto err_no_charger_stat;
+ }
+
+ /* Counting index only */
+ while (desc->psy_charger_stat[i])
+ i++;
+
+ cm->charger_stat = kzalloc(sizeof(struct power_supply *) * (i + 1),
+ GFP_KERNEL);
+ if (!cm->charger_stat) {
+ ret = -ENOMEM;
+ goto err_no_charger_stat;
+ }
+
+ for (i = 0; desc->psy_charger_stat[i]; i++) {
+ cm->charger_stat[i] = power_supply_get_by_name(
+ desc->psy_charger_stat[i]);
+ if (!cm->charger_stat[i]) {
+ dev_err(&pdev->dev, "Cannot find power supply "
+ "\"%s\"\n",
+ desc->psy_charger_stat[i]);
+ ret = -ENODEV;
+ goto err_chg_stat;
+ }
+ }
+
+ cm->fuel_gauge = power_supply_get_by_name(desc->psy_fuel_gauge);
+ if (!cm->fuel_gauge) {
+ dev_err(&pdev->dev, "Cannot find power supply \"%s\"\n",
+ desc->psy_fuel_gauge);
+ ret = -ENODEV;
+ goto err_chg_stat;
+ }
+
+ if (desc->polling_interval_ms == 0 ||
+ msecs_to_jiffies(desc->polling_interval_ms) <= CM_JIFFIES_SMALL) {
+ dev_err(&pdev->dev, "polling_interval_ms is too small\n");
+ ret = -EINVAL;
+ goto err_chg_stat;
+ }
+
+ if (!desc->temperature_out_of_range) {
+ dev_err(&pdev->dev, "there is no temperature_out_of_range\n");
+ ret = -EINVAL;
+ goto err_chg_stat;
+ }
+
+ platform_set_drvdata(pdev, cm);
+
+ memcpy(&cm->charger_psy, &psy_default,
+ sizeof(psy_default));
+ if (!desc->psy_name) {
+ strncpy(cm->psy_name_buf, psy_default.name,
+ PSY_NAME_MAX);
+ } else {
+ strncpy(cm->psy_name_buf, desc->psy_name, PSY_NAME_MAX);
+ }
+ cm->charger_psy.name = cm->psy_name_buf;
+
+ /* Allocate for psy properties because they may vary */
+ cm->charger_psy.properties = kzalloc(sizeof(enum power_supply_property)
+ * (ARRAY_SIZE(default_charger_props) +
+ NUM_CHARGER_PSY_OPTIONAL),
+ GFP_KERNEL);
+ if (!cm->charger_psy.properties) {
+ dev_err(&pdev->dev, "Cannot allocate for psy properties.\n");
+ ret = -ENOMEM;
+ goto err_chg_stat;
+ }
+ memcpy(cm->charger_psy.properties, default_charger_props,
+ sizeof(enum power_supply_property) *
+ ARRAY_SIZE(default_charger_props));
+ cm->charger_psy.num_properties = psy_default.num_properties;
+
+ /* Find which optional psy-properties are available */
+ if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CHARGE_NOW, &val)) {
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
+ POWER_SUPPLY_PROP_CHARGE_NOW;
+ cm->charger_psy.num_properties++;
+ }
+ if (!cm->fuel_gauge->get_property(cm->fuel_gauge,
+ POWER_SUPPLY_PROP_CURRENT_NOW,
+ &val)) {
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
+ POWER_SUPPLY_PROP_CURRENT_NOW;
+ cm->charger_psy.num_properties++;
+ }
+ if (!desc->measure_battery_temp) {
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
+ POWER_SUPPLY_PROP_TEMP_AMBIENT;
+ cm->charger_psy.num_properties++;
+ }
+ if (desc->measure_battery_temp) {
+ cm->charger_psy.properties[cm->charger_psy.num_properties] =
+ POWER_SUPPLY_PROP_TEMP;
+ cm->charger_psy.num_properties++;
+ }
+
+ ret = power_supply_register(NULL, &cm->charger_psy);
+ if (ret) {
+ dev_err(&pdev->dev, "Cannot register charger-manager with"
+ " name \"%s\".\n", cm->charger_psy.name);
+ goto err_register;
+ }
+
+ ret = regulator_bulk_get(&pdev->dev, desc->num_charger_regulators,
+ desc->charger_regulators);
+ if (ret) {
+ dev_err(&pdev->dev, "Cannot get charger regulators.\n");
+ goto err_bulk_get;
+ }
+
+ ret = try_charger_enable(cm, true);
+ if (ret) {
+ dev_err(&pdev->dev, "Cannot enable charger regulators\n");
+ goto err_chg_enable;
+ }
+
+ /* Add to the list */
+ mutex_lock(&cm_list_mtx);
+ list_add(&cm->entry, &cm_list);
+ mutex_unlock(&cm_list_mtx);
+
+ return 0;
+
+err_chg_enable:
+ if (desc->charger_regulators)
+ regulator_bulk_free(desc->num_charger_regulators,
+ desc->charger_regulators);
+err_bulk_get:
+ power_supply_unregister(&cm->charger_psy);
+err_register:
+ kfree(cm->charger_psy.properties);
+err_chg_stat:
+ kfree(cm->charger_stat);
+err_no_charger_stat:
+err_no_charger:
+ kfree(cm->desc);
+err_alloc_desc:
+ kfree(cm);
+err_alloc:
+ return ret;
+}
+
+static int __devexit charger_manager_remove(struct platform_device *pdev)
+{
+ struct charger_manager *cm = platform_get_drvdata(pdev);
+ struct charger_desc *desc = cm->desc;
+
+ /* Remove from the list */
+ mutex_lock(&cm_list_mtx);
+ list_del(&cm->entry);
+ mutex_unlock(&cm_list_mtx);
+
+ if (desc->charger_regulators)
+ regulator_bulk_free(desc->num_charger_regulators,
+ desc->charger_regulators);
+
+ power_supply_unregister(&cm->charger_psy);
+ kfree(cm->charger_psy.properties);
+ kfree(cm->charger_stat);
+ kfree(cm->desc);
+ kfree(cm);
+
+ return 0;
+}
+
+const struct platform_device_id charger_manager_id[] = {
+ { "charger-manager", 0 },
+ { },
+};
+
+static int cm_suspend_prepare(struct device *dev)
+{
+ struct platform_device *pdev = container_of(dev, struct platform_device,
+ dev);
+ struct charger_manager *cm = platform_get_drvdata(pdev);
+
+ if (!cm_suspended) {
+ if (rtc_dev) {
+ struct rtc_time tmp;
+ unsigned long now;
+
+ rtc_read_alarm(rtc_dev, &rtc_wkalarm_save);
+ rtc_read_time(rtc_dev, &tmp);
+
+ if (rtc_wkalarm_save.enabled) {
+ rtc_tm_to_time(&rtc_wkalarm_save.time,
+ &rtc_wkalarm_save_time);
+ rtc_tm_to_time(&tmp, &now);
+ if (now > rtc_wkalarm_save_time)
+ rtc_wkalarm_save_time = 0;
+ } else {
+ rtc_wkalarm_save_time = 0;
+ }
+ }
+ cm_suspended = true;
+ }
+
+ cm->status_save_ext_pwr_inserted = is_ext_pwr_online(cm);
+ cm->status_save_batt = is_batt_present(cm);
+
+ if (!cm_rtc_set) {
+ cm_suspend_duration_ms = 0;
+ cm_rtc_set = cm_setup_timer();
+ }
+
+ return 0;
+}
+
+static void cm_suspend_complete(struct device *dev)
+{
+ struct platform_device *pdev = container_of(dev, struct platform_device,
+ dev);
+ struct charger_manager *cm = platform_get_drvdata(pdev);
+
+ if (cm_suspended) {
+ if (rtc_dev) {
+ struct rtc_wkalrm tmp;
+
+ rtc_read_alarm(rtc_dev, &tmp);
+ rtc_wkalarm_save.pending = tmp.pending;
+ rtc_set_alarm(rtc_dev, &rtc_wkalarm_save);
+ }
+ cm_suspended = false;
+ cm_rtc_set = false;
+ }
+
+ uevent_notify(cm, NULL);
+}
+
+static const struct dev_pm_ops charger_manager_pm = {
+ .prepare = cm_suspend_prepare,
+ .complete = cm_suspend_complete,
+};
+
+static struct platform_driver charger_manager_driver = {
+ .driver = {
+ .name = "charger-manager",
+ .owner = THIS_MODULE,
+ .pm = &charger_manager_pm,
+ },
+ .probe = charger_manager_probe,
+ .remove = __devexit_p(charger_manager_remove),
+ .id_table = charger_manager_id,
+};
+
+static int __init charger_manager_init(void)
+{
+ return platform_driver_register(&charger_manager_driver);
+}
+late_initcall(charger_manager_init);
+
+static void __exit charger_manager_cleanup(void)
+{
+ platform_driver_unregister(&charger_manager_driver);
+}
+module_exit(charger_manager_cleanup);
+
+MODULE_AUTHOR("MyungJoo Ham <myungjoo.ham@samsung.com>");
+MODULE_DESCRIPTION("Charger Manager");
+MODULE_LICENSE("GPL");
+MODULE_ALIAS("charger-manager");