authorAlan Stern <stern@rowland.harvard.edu>2008-03-11 10:20:12 -0400
committerGreg Kroah-Hartman <gregkh@suse.de>2008-03-24 22:26:14 -0700
commit392e1d9817d0024c96aae237c3c4349e47c976fd (patch)
tree41fb12fe0d67f36773c1dd5c2e70f51e37c30594 /include/linux
parent12cd5b984f825c5448aa4c0df561f8252076fd52 (diff)
USB: new quirk flag to avoid Set-Interface
This patch (as1057) fixes a problem with the X-Rite/Gretag-Macbeth Eye-One Pro display colorimeter; the device crashes when it receives a Set-Interface request. A new quirk (USB_QUIRK_NO_SET_INTF) is introduced and a quirks entry is created for this device. Signed-off-by: Alan Stern <stern@rowland.harvard.edu> Cc: stable <stable@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@suse.de>
Diffstat (limited to 'include/linux')
-rw-r--r--include/linux/usb/quirks.h3
1 files changed, 3 insertions, 0 deletions
diff --git a/include/linux/usb/quirks.h b/include/linux/usb/quirks.h
index 2692ec9389ca..1f999ec8d08c 100644
--- a/include/linux/usb/quirks.h
+++ b/include/linux/usb/quirks.h
@@ -9,3 +9,6 @@
/* device can't resume correctly so reset it instead */
#define USB_QUIRK_RESET_RESUME 0x00000002
+
+/* device can't handle Set-Interface requests */
+#define USB_QUIRK_NO_SET_INTF 0x00000004