powerpc/pseries: All events of EPOW_SYSTEM_SHUTDOWN must initiate shutdown
The current handling of EPOW_SHUTDOWN_ON_UPS event does not shutdown the
system after logging the message. All the events of EPOW_SYSTEM_SHUTDOWN
action code (EPOW_SHUTDOWN_ON_UPS is a part of it) must initiate system
shutdown as per the SPAPR spec. If the LPAR does not shutdown after
receiving this rtas based event, it will expose itself to a forced
abrupt shutdown initiated by the platform firmware. This patch fixes the
situation.
Signed-off-by: Anshuman Khandual <khandual@linux.vnet.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
-rw-r--r-- | arch/powerpc/platforms/pseries/ras.c | 2 |
1 files changed, 2 insertions, 0 deletions
diff --git a/arch/powerpc/platforms/pseries/ras.c b/arch/powerpc/platforms/pseries/ras.c index c3b2a7e81ddb..02e4a1745516 100644 --- a/arch/powerpc/platforms/pseries/ras.c +++ b/arch/powerpc/platforms/pseries/ras.c @@ -89,6 +89,8 @@ static void handle_system_shutdown(char event_modifier) case EPOW_SHUTDOWN_ON_UPS: pr_emerg("Loss of power reported by firmware, system is " "running on UPS/battery"); + pr_emerg("Check RTAS error log for details"); + orderly_poweroff(true); break; case EPOW_SHUTDOWN_LOSS_OF_CRITICAL_FUNCTIONS: |