diff options
author | Linus Torvalds <torvalds@linux-foundation.org> | 2014-11-12 13:15:18 -0800 |
---|---|---|
committer | Linus Torvalds <torvalds@linux-foundation.org> | 2014-11-12 13:15:18 -0800 |
commit | 999f81dd1937f2a9e56ce40e98be00758668ca19 (patch) | |
tree | f321cbc4409d5658f696b91aef538de32a92af1d /drivers | |
parent | c9212201150b70b19fa63c356eb84e1ae6532622 (diff) | |
parent | 90a21ff5824c3ae8b49c1c0498b137792b935aab (diff) |
Merge branch 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal
Pull thermal driver fixes from Eduardo Valentin:
"This week we have few fixes:
- fix in IMX thermal driver to do the correct loading sequence with
CPUfreq
- fix in Exynos related to TMU_CONTROL offset in Exynos5260
- fix the unit conversion in int3403"
[ Still pulling from Eduardo as Rui Zhang is on a business trip and has
troubles with his machine ]
* 'fixes' of git://git.kernel.org/pub/scm/linux/kernel/git/evalenti/linux-soc-thermal:
imx: thermal: imx_get_temp might be called before sensor clock is prepared
thermal: exynos: use correct offset for TMU_CONTROL register on Exynos5260
thermal: imx: correct driver load sequence for cpu cooling
Thermal/int3403: Fix thermal hysteresis unit conversion
Diffstat (limited to 'drivers')
-rw-r--r-- | drivers/thermal/imx_thermal.c | 45 | ||||
-rw-r--r-- | drivers/thermal/int340x_thermal/int3403_thermal.c | 8 | ||||
-rw-r--r-- | drivers/thermal/samsung/exynos_tmu_data.c | 1 | ||||
-rw-r--r-- | drivers/thermal/samsung/exynos_tmu_data.h | 1 |
4 files changed, 36 insertions, 19 deletions
diff --git a/drivers/thermal/imx_thermal.c b/drivers/thermal/imx_thermal.c index 461bf3d033a0..5a1f1070b702 100644 --- a/drivers/thermal/imx_thermal.c +++ b/drivers/thermal/imx_thermal.c @@ -459,6 +459,10 @@ static int imx_thermal_probe(struct platform_device *pdev) int measure_freq; int ret; + if (!cpufreq_get_current_driver()) { + dev_dbg(&pdev->dev, "no cpufreq driver!"); + return -EPROBE_DEFER; + } data = devm_kzalloc(&pdev->dev, sizeof(*data), GFP_KERNEL); if (!data) return -ENOMEM; @@ -521,6 +525,30 @@ static int imx_thermal_probe(struct platform_device *pdev) return ret; } + data->thermal_clk = devm_clk_get(&pdev->dev, NULL); + if (IS_ERR(data->thermal_clk)) { + ret = PTR_ERR(data->thermal_clk); + if (ret != -EPROBE_DEFER) + dev_err(&pdev->dev, + "failed to get thermal clk: %d\n", ret); + cpufreq_cooling_unregister(data->cdev); + return ret; + } + + /* + * Thermal sensor needs clk on to get correct value, normally + * we should enable its clk before taking measurement and disable + * clk after measurement is done, but if alarm function is enabled, + * hardware will auto measure the temperature periodically, so we + * need to keep the clk always on for alarm function. + */ + ret = clk_prepare_enable(data->thermal_clk); + if (ret) { + dev_err(&pdev->dev, "failed to enable thermal clk: %d\n", ret); + cpufreq_cooling_unregister(data->cdev); + return ret; + } + data->tz = thermal_zone_device_register("imx_thermal_zone", IMX_TRIP_NUM, BIT(IMX_TRIP_PASSIVE), data, @@ -531,26 +559,11 @@ static int imx_thermal_probe(struct platform_device *pdev) ret = PTR_ERR(data->tz); dev_err(&pdev->dev, "failed to register thermal zone device %d\n", ret); + clk_disable_unprepare(data->thermal_clk); cpufreq_cooling_unregister(data->cdev); return ret; } - data->thermal_clk = devm_clk_get(&pdev->dev, NULL); - if (IS_ERR(data->thermal_clk)) { - dev_warn(&pdev->dev, "failed to get thermal clk!\n"); - } else { - /* - * Thermal sensor needs clk on to get correct value, normally - * we should enable its clk before taking measurement and disable - * clk after measurement is done, but if alarm function is enabled, - * hardware will auto measure the temperature periodically, so we - * need to keep the clk always on for alarm function. - */ - ret = clk_prepare_enable(data->thermal_clk); - if (ret) - dev_warn(&pdev->dev, "failed to enable thermal clk: %d\n", ret); - } - /* Enable measurements at ~ 10 Hz */ regmap_write(map, TEMPSENSE1 + REG_CLR, TEMPSENSE1_MEASURE_FREQ); measure_freq = DIV_ROUND_UP(32768, 10); /* 10 Hz */ diff --git a/drivers/thermal/int340x_thermal/int3403_thermal.c b/drivers/thermal/int340x_thermal/int3403_thermal.c index d20dba986f0f..6e9fb62eb817 100644 --- a/drivers/thermal/int340x_thermal/int3403_thermal.c +++ b/drivers/thermal/int340x_thermal/int3403_thermal.c @@ -92,7 +92,13 @@ static int sys_get_trip_hyst(struct thermal_zone_device *tzone, if (ACPI_FAILURE(status)) return -EIO; - *temp = DECI_KELVIN_TO_MILLI_CELSIUS(hyst, KELVIN_OFFSET); + /* + * Thermal hysteresis represents a temperature difference. + * Kelvin and Celsius have same degree size. So the + * conversion here between tenths of degree Kelvin unit + * and Milli-Celsius unit is just to multiply 100. + */ + *temp = hyst * 100; return 0; } diff --git a/drivers/thermal/samsung/exynos_tmu_data.c b/drivers/thermal/samsung/exynos_tmu_data.c index 2683d2897e90..1724f6cdaef8 100644 --- a/drivers/thermal/samsung/exynos_tmu_data.c +++ b/drivers/thermal/samsung/exynos_tmu_data.c @@ -264,7 +264,6 @@ struct exynos_tmu_init_data const exynos5250_default_tmu_data = { static const struct exynos_tmu_registers exynos5260_tmu_registers = { .triminfo_data = EXYNOS_TMU_REG_TRIMINFO, .tmu_ctrl = EXYNOS_TMU_REG_CONTROL, - .tmu_ctrl = EXYNOS_TMU_REG_CONTROL1, .therm_trip_mode_shift = EXYNOS_TMU_TRIP_MODE_SHIFT, .therm_trip_mode_mask = EXYNOS_TMU_TRIP_MODE_MASK, .therm_trip_en_shift = EXYNOS_TMU_THERM_TRIP_EN_SHIFT, diff --git a/drivers/thermal/samsung/exynos_tmu_data.h b/drivers/thermal/samsung/exynos_tmu_data.h index 65e2ea6a9579..63de598c9c2c 100644 --- a/drivers/thermal/samsung/exynos_tmu_data.h +++ b/drivers/thermal/samsung/exynos_tmu_data.h @@ -75,7 +75,6 @@ #define EXYNOS_MAX_TRIGGER_PER_REG 4 /* Exynos5260 specific */ -#define EXYNOS_TMU_REG_CONTROL1 0x24 #define EXYNOS5260_TMU_REG_INTEN 0xC0 #define EXYNOS5260_TMU_REG_INTSTAT 0xC4 #define EXYNOS5260_TMU_REG_INTCLEAR 0xC8 |