summaryrefslogtreecommitdiff
path: root/drivers/net
diff options
context:
space:
mode:
authorJian Shen <shenjian15@huawei.com>2019-12-05 10:12:29 +0800
committerDavid S. Miller <davem@davemloft.net>2019-12-05 14:42:43 -0800
commit1c9855085ebaaa2efcf368bee038e4811015abbd (patch)
treebc30a5c307a3a613ccf40198c97c2c68e21378c7 /drivers/net
parentd1a37dedcfcf2c01daff5281c3c378876a04e2f4 (diff)
net: hns3: fix VF ID issue for setting VF VLAN
Previously, when set VF VLAN with command "ip link set <pf name> vf <vf id> vlan <vlan id>", the VF ID 0 is handled as PF incorrectly, which should be the first VF. This patch fixes it. Fixes: 21e043cd8124 ("net: hns3: fix set port based VLAN for PF") Signed-off-by: Jian Shen <shenjian15@huawei.com> Signed-off-by: Huazhong Tan <tanhuazhong@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
Diffstat (limited to 'drivers/net')
-rw-r--r--drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_main.c18
1 files changed, 6 insertions, 12 deletions
diff --git a/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_main.c b/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_main.c
index 7c7038676d6d..d862e9ba27e1 100644
--- a/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_main.c
+++ b/drivers/net/ethernet/hisilicon/hns3/hns3pf/hclge_main.c
@@ -8438,13 +8438,16 @@ static int hclge_set_vf_vlan_filter(struct hnae3_handle *handle, int vfid,
if (hdev->pdev->revision == 0x20)
return -EOPNOTSUPP;
+ vport = hclge_get_vf_vport(hdev, vfid);
+ if (!vport)
+ return -EINVAL;
+
/* qos is a 3 bits value, so can not be bigger than 7 */
- if (vfid >= hdev->num_alloc_vfs || vlan > VLAN_N_VID - 1 || qos > 7)
+ if (vlan > VLAN_N_VID - 1 || qos > 7)
return -EINVAL;
if (proto != htons(ETH_P_8021Q))
return -EPROTONOSUPPORT;
- vport = &hdev->vport[vfid];
state = hclge_get_port_base_vlan_state(vport,
vport->port_base_vlan_cfg.state,
vlan);
@@ -8455,21 +8458,12 @@ static int hclge_set_vf_vlan_filter(struct hnae3_handle *handle, int vfid,
vlan_info.qos = qos;
vlan_info.vlan_proto = ntohs(proto);
- /* update port based VLAN for PF */
- if (!vfid) {
- hclge_notify_client(hdev, HNAE3_DOWN_CLIENT);
- ret = hclge_update_port_base_vlan_cfg(vport, state, &vlan_info);
- hclge_notify_client(hdev, HNAE3_UP_CLIENT);
-
- return ret;
- }
-
if (!test_bit(HCLGE_VPORT_STATE_ALIVE, &vport->state)) {
return hclge_update_port_base_vlan_cfg(vport, state,
&vlan_info);
} else {
ret = hclge_push_vf_port_base_vlan_info(&hdev->vport[0],
- (u8)vfid, state,
+ vport->vport_id, state,
vlan, qos,
ntohs(proto));
return ret;