summaryrefslogtreecommitdiff
path: root/Documentation/power
diff options
context:
space:
mode:
authorLinus Torvalds <torvalds@linux-foundation.org>2012-07-31 18:08:25 -0700
committerLinus Torvalds <torvalds@linux-foundation.org>2012-07-31 18:08:25 -0700
commit4b24ff71108164e047cf2c95990b77651163e315 (patch)
tree4b478906379adf22ff259fc1f2cce0da796df415 /Documentation/power
parentbca1a5c0eabe0f17081760c61e8d08e73dd6b6a6 (diff)
parent4b1bf5871f7d59de6484cc887e205d6d2f1e6fbd (diff)
Merge tag 'for-v3.6' of git://git.infradead.org/battery-2.6
Pull battery updates from Anton Vorontsov: "The tag contains just a few battery-related changes for v3.6. It's is all pretty straightforward, except one thing. One of our patches added thermal support for power supply class, but thermal/ subsystem changed under our feet. We (well, Stephen, that is) caught the issue and it was decided[1] that I'd just delay the battery pull request, and then will fix it up by merging upstream back into battery tree at the specific commit. That's not all though: another[2] small fixup for thermal subsystem was needed to get rid of a warning in power supply subsystem (the warning was not drivers/power's "fault", the thermal registration function just needed a proper const annotation, which is also done by a small commit on top of the merge. So, to sum this up: - The 'master' branch of the battery tree was in the -next tree for weeks, was never rebased, altered etc. It should be all OK; - Although, for-v3.6 tag contains the 'master' branch + merge + the warning fix. [1] http://lkml.org/lkml/2012/6/19/23 [2] http://lkml.org/lkml/2012/6/18/28" * tag 'for-v3.6' of git://git.infradead.org/battery-2.6: (23 commits) thermal: Constify 'type' argument for the registration routine olpc-battery: update CHARGE_FULL_DESIGN property for BYD LiFe batteries olpc-battery: Add VOLTAGE_MAX_DESIGN property charger-manager: Fix build break related to EXTCON lp8727_charger: Move header file into platform_data directory power_supply: Add min/max alert properties for CAPACITY, TEMP, TEMP_AMBIENT bq27x00_battery: Add support for BQ27425 chip charger-manager: Set current limit of regulator for over current protection charger-manager: Use EXTCON Subsystem to detect charger cables for charging test_power: Add VOLTAGE_NOW and BATTERY_TEMP properties test_power: Add support for USB AC source gpio-charger: Use cansleep version of gpio_set_value bq27x00_battery: Add support for power average and health properties sbs-battery: Don't trigger false supply_changed event twl4030_charger: Allow charger to control the regulator that feeds it twl4030_charger: Add backup-battery charging twl4030_charger: Fix some typos max17042_battery: Support CHARGE_COUNTER power supply attribute smb347-charger: Add constant charge and current properties power_supply: Add constant charge_current and charge_voltage properties ...
Diffstat (limited to 'Documentation/power')
-rw-r--r--Documentation/power/power_supply_class.txt10
1 files changed, 10 insertions, 0 deletions
diff --git a/Documentation/power/power_supply_class.txt b/Documentation/power/power_supply_class.txt
index 211831d4095f..2f0ddc15b5ac 100644
--- a/Documentation/power/power_supply_class.txt
+++ b/Documentation/power/power_supply_class.txt
@@ -112,14 +112,24 @@ CHARGE_COUNTER - the current charge counter (in µAh). This could easily
be negative; there is no empty or full value. It is only useful for
relative, time-based measurements.
+CONSTANT_CHARGE_CURRENT - constant charge current programmed by charger.
+
+CONSTANT_CHARGE_VOLTAGE - constant charge voltage programmed by charger.
+
ENERGY_FULL, ENERGY_EMPTY - same as above but for energy.
CAPACITY - capacity in percents.
+CAPACITY_ALERT_MIN - minimum capacity alert value in percents.
+CAPACITY_ALERT_MAX - maximum capacity alert value in percents.
CAPACITY_LEVEL - capacity level. This corresponds to
POWER_SUPPLY_CAPACITY_LEVEL_*.
TEMP - temperature of the power supply.
+TEMP_ALERT_MIN - minimum battery temperature alert value in milli centigrade.
+TEMP_ALERT_MAX - maximum battery temperature alert value in milli centigrade.
TEMP_AMBIENT - ambient temperature.
+TEMP_AMBIENT_ALERT_MIN - minimum ambient temperature alert value in milli centigrade.
+TEMP_AMBIENT_ALERT_MAX - maximum ambient temperature alert value in milli centigrade.
TIME_TO_EMPTY - seconds left for battery to be considered empty (i.e.
while battery powers a load)