From aa3d4409b664813ceb86a24bd09458cdd29cbb8a Mon Sep 17 00:00:00 2001 From: Martin Kepplinger Date: Mon, 22 May 2017 17:19:45 -0700 Subject: Input: edt-ft5x06 - increase allowed data range for threshold parameter The datasheet and application note does not mention an allowed range for the M09_REGISTER_THRESHOLD parameter. One of our customers needs to set lower values than 20 and they seem to work just fine on EDT EP0xx0M09 with T5x06 touch. So, lacking a known lower limit, we increase the range for thresholds, and set the lower limit to 0. The documentation is updated accordingly. Signed-off-by: Schoefegger Stefan Signed-off-by: Manfred Schlaegl Signed-off-by: Martin Kepplinger Acked-by: Rob Herring Signed-off-by: Dmitry Torokhov --- drivers/input/touchscreen/edt-ft5x06.c | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) (limited to 'drivers/input') diff --git a/drivers/input/touchscreen/edt-ft5x06.c b/drivers/input/touchscreen/edt-ft5x06.c index 8cf8d8d5d4ef..f872817e81e4 100644 --- a/drivers/input/touchscreen/edt-ft5x06.c +++ b/drivers/input/touchscreen/edt-ft5x06.c @@ -471,7 +471,7 @@ static EDT_ATTR(gain, S_IWUSR | S_IRUGO, WORK_REGISTER_GAIN, static EDT_ATTR(offset, S_IWUSR | S_IRUGO, WORK_REGISTER_OFFSET, M09_REGISTER_OFFSET, 0, 31); static EDT_ATTR(threshold, S_IWUSR | S_IRUGO, WORK_REGISTER_THRESHOLD, - M09_REGISTER_THRESHOLD, 20, 80); + M09_REGISTER_THRESHOLD, 0, 80); static EDT_ATTR(report_rate, S_IWUSR | S_IRUGO, WORK_REGISTER_REPORT_RATE, NO_REGISTER, 3, 14); -- cgit v1.2.3