diff options
Diffstat (limited to 'kernel/cgroup')
-rw-r--r-- | kernel/cgroup/cpuset.c | 34 |
1 files changed, 27 insertions, 7 deletions
diff --git a/kernel/cgroup/cpuset.c b/kernel/cgroup/cpuset.c index 82c88c60c83d..3960de7a75cc 100644 --- a/kernel/cgroup/cpuset.c +++ b/kernel/cgroup/cpuset.c @@ -769,13 +769,14 @@ static int generate_sched_domains(cpumask_var_t **domains, int ndoms = 0; /* number of sched domains in result */ int nslot; /* next empty doms[] struct cpumask slot */ struct cgroup_subsys_state *pos_css; + bool root_load_balance = is_sched_load_balance(&top_cpuset); doms = NULL; dattr = NULL; csa = NULL; /* Special case for the 99% of systems with one, full, sched domain */ - if (is_sched_load_balance(&top_cpuset)) { + if (root_load_balance && !top_cpuset.nr_subparts_cpus) { ndoms = 1; doms = alloc_sched_domains(ndoms); if (!doms) @@ -798,6 +799,8 @@ static int generate_sched_domains(cpumask_var_t **domains, csn = 0; rcu_read_lock(); + if (root_load_balance) + csa[csn++] = &top_cpuset; cpuset_for_each_descendant_pre(cp, pos_css, &top_cpuset) { if (cp == &top_cpuset) continue; @@ -808,6 +811,9 @@ static int generate_sched_domains(cpumask_var_t **domains, * parent's cpus, so just skip them, and then we call * update_domain_attr_tree() to calc relax_domain_level of * the corresponding sched domain. + * + * If root is load-balancing, we can skip @cp if it + * is a subset of the root's effective_cpus. */ if (!cpumask_empty(cp->cpus_allowed) && !(is_sched_load_balance(cp) && @@ -815,11 +821,16 @@ static int generate_sched_domains(cpumask_var_t **domains, housekeeping_cpumask(HK_FLAG_DOMAIN)))) continue; + if (root_load_balance && + cpumask_subset(cp->cpus_allowed, top_cpuset.effective_cpus)) + continue; + if (is_sched_load_balance(cp)) csa[csn++] = cp; - /* skip @cp's subtree */ - pos_css = css_rightmost_descendant(pos_css); + /* skip @cp's subtree if not a partition root */ + if (!is_partition_root(cp)) + pos_css = css_rightmost_descendant(pos_css); } rcu_read_unlock(); @@ -947,7 +958,12 @@ static void rebuild_sched_domains_locked(void) * passing doms with offlined cpu to partition_sched_domains(). * Anyways, hotplug work item will rebuild sched domains. */ - if (!cpumask_equal(top_cpuset.effective_cpus, cpu_active_mask)) + if (!top_cpuset.nr_subparts_cpus && + !cpumask_equal(top_cpuset.effective_cpus, cpu_active_mask)) + goto out; + + if (top_cpuset.nr_subparts_cpus && + !cpumask_subset(top_cpuset.effective_cpus, cpu_active_mask)) goto out; /* Generate domain masks and attrs */ @@ -1367,11 +1383,15 @@ static void update_cpumasks_hier(struct cpuset *cs, struct tmpmasks *tmp) update_tasks_cpumask(cp); /* - * If the effective cpumask of any non-empty cpuset is changed, - * we need to rebuild sched domains. + * On legacy hierarchy, if the effective cpumask of any non- + * empty cpuset is changed, we need to rebuild sched domains. + * On default hierarchy, the cpuset needs to be a partition + * root as well. */ if (!cpumask_empty(cp->cpus_allowed) && - is_sched_load_balance(cp)) + is_sched_load_balance(cp) && + (!cgroup_subsys_on_dfl(cpuset_cgrp_subsys) || + is_partition_root(cp))) need_rebuild_sched_domains = true; rcu_read_lock(); |